DRY AND WET-PEAKING TOWER COOLING SYSTEMS FOR POWER-PLANT APPLICATION

被引:0
|
作者
LARINOFF, MW [1 ]
FORSTER, LL [1 ]
机构
[1] INGERSOLL RAND CO,E BRUNSWICK,NJ
来源
COMBUSTION | 1977年 / 48卷 / 11期
关键词
POWER PLANTS - Heat Sinks - WATER COOLING TOWERS - Design;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new concept of power plant heat-sink system is presented which employs the combination of a conventional wet-tower and a conventional dry-tower. The purpose of this cooling system is to reduce wet cooling-tower makeup-water requirements in water-short areas. The dry tower operates all year around while the wet-peaking tower is used only above certain ambient dry-bulb temperatures. The two cooling circuits serve separate sections of a conventional, surface-type, steam condenser. Thermal performance analysis is presented for various combinations of cooling systems ranging from 100 percent wet to 100 percent dry. Annual makeup-water requirements are calculated for various sizes of towers located in 18 selected cities of the U. S. A. , ranging from north to south and east to west.
引用
收藏
页码:8 / 21
页数:14
相关论文
共 50 条
  • [41] OPTIMIZING COOLING POLICY FOR POWER-PLANT SYSTEM
    LUM, L
    MAYS, LW
    JOURNAL OF THE ENERGY DIVISION-ASCE, 1979, 105 (01): : 137 - 155
  • [42] APPLICATION OF MULTIPLE LINEAR-REGRESSION TO POWER-PLANT COOLING SYSTEM SIMULATION
    LI, KW
    MATSUOKA, K
    CASHMAN, JH
    ELECTRIC POWER SYSTEMS RESEARCH, 1979, 2 (04) : 309 - 311
  • [43] Wet and dry cooling systems optimization applied to a modern waste-to-energy cogeneration heat and power plant
    Barigozzi, G.
    Perdichizzi, A.
    Ravelli, S.
    APPLIED ENERGY, 2011, 88 (04) : 1366 - 1376
  • [44] Mátra power plant, Hungary - FGD retrofit with the scrubber in the dry cooling tower
    Ludanyi, G.
    Stöckmann, H.
    Heiting, B.
    2001, VGB-Kraftswerktechnik GmbH (81):
  • [45] PARAMETRIC STUDY OF BUOYANT WET POWER-PLANT PLUMES
    DEBOWER, KK
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1978, 59 (09) : 1248 - 1248
  • [46] Investigation on the cooling performance of mechanical draft dry-wet hybrid cooling tower
    Zhao, Cuilin
    Wang, Mingwei
    Gao, Qi
    Cheng, Shen
    He, Suoying
    Zhao, Jifang
    Zhan, Jianwei
    Liu, Zhilan
    Geng, Zhe
    Zhang, Shuzhen
    Qi, Jianhui
    Gao, Ming
    Shi, Yuetao
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [48] PLUME ABATEMENT AND WATER CONSERVATION WITH WET-DRY COOLING TOWER
    LANDON, RD
    HOUX, JR
    COMBUSTION, 1973, 5 (03): : 28 - 28
  • [49] VISIBLE PLUME ABATEMENT WITH WET-DRY COOLING-TOWER
    RUBIN, AM
    KLANIAN, PS
    POWER ENGINEERING, 1975, 79 (03) : 54 - 57
  • [50] THERMODYNAMIC STUDIES ON A WET-DRY CELL COOLING-TOWER
    KOKOTT, D
    CHEMIE INGENIEUR TECHNIK, 1978, 50 (07) : 546 - 547