DIAGNOSTIC-ACCURACY OF SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN ALZHEIMERS-DISEASE

被引:0
|
作者
HANYU, H
ABE, S
ARAI, H
ASANO, T
IWAMOTO, T
TAKASAKI, M
机构
关键词
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; CEREBRAL PERFUSION; ALZHEIMERS DISEASE; DIAGNOSIS;
D O I
暂无
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
To determine whether the detection of parietotemporal functional abnormalities as demonstrated by single photon emission computed tomography (SPECT) can be employed as a diagnostic marker for Alzheimer's disease (AD), we studied 219 patients with neurologic disorders including 56 with AD and 25 healthy controls. The diagnostic sensitivity (parieto-temporal hypoperfusion present in AD patients) was 82%, and the specificity (parietotemporal hypoperfusion absent in non-AD patients and controls) was 89%. These results suggest that SPECT imaging provides an accurate and sensitive diagnostic test for AD.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [31] BONE IMAGING USING SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    GATES, GF
    WESTERN JOURNAL OF MEDICINE, 1994, 161 (04): : 410 - 411
  • [34] SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN CHILDREN WITH PARTIAL EPILEPSY
    LOPEZMARTIN, V
    ARCAS, J
    MARTINEZBERMEJO, A
    COYA, A
    ROCHE, C
    CASTROVIEJO, I
    TENDERO, A
    EPILEPSIA, 1995, 36 : S133 - S133
  • [35] TETRAHYDROAMINOACRIDINE MODULATES TC-99M LABELED ETHYLENE DICYSTEINATE RETENTION IN ALZHEIMERS-DISEASE MEASURED WITH SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGING
    RIEKKINEN, P
    KUIKKA, J
    SOININEN, H
    HELKALA, EL
    HALLIKAINEN, M
    RIEKKINEN, P
    NEUROSCIENCE LETTERS, 1995, 195 (01) : 53 - 56
  • [36] Diagnostic accuracy of coronary computed tomography angiography and single-photon emission computed tomography in renal transplantation candidates
    Winther, S.
    Svensson, M.
    Jorgensen, H. S.
    Bouchelouche, K.
    Gormsen, L. C.
    Holm, N. R.
    Botker, H. E.
    Ivarsen, P.
    Bottcher, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 453 - 453
  • [37] THE INVESTIGATION OF ALZHEIMERS-DISEASE WITH SINGLE PHOTON-EMISSION TOMOGRAPHY
    BURNS, A
    PHILPOT, MP
    COSTA, DC
    ELL, PJ
    LEVY, R
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1989, 52 (02): : 248 - 253
  • [38] BRAIN IMAGING - COMPUTED-TOMOGRAPHY IN ALZHEIMERS-DISEASE
    BURNS, A
    LANCET, 1993, 341 (8845): : 601 - 602
  • [39] ATTENUATION CORRECTION IN CARDIAC POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    BACHARACH, SL
    BUVAT, I
    JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (03) : 246 - 255
  • [40] INTERICTAL SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN PARTIAL EPILEPSY - ACCURACY IN LOCALIZATION AND PREDICTION OF OUTCOME
    TATUM, WO
    OCONNOR, MJ
    SPERLING, MR
    JACOBSTEIN, JG
    JOURNAL OF NEUROIMAGING, 1995, 5 (03) : 142 - 144