PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN

被引:87
|
作者
SCHWARTZ, LH [1 ]
SELTZER, SE [1 ]
TEMPANY, CMC [1 ]
SILVERMAN, SG [1 ]
PIWNICAWORMS, DR [1 ]
ADAMS, DF [1 ]
HERMAN, L [1 ]
HERMAN, LT [1 ]
HOOSHMAND, R [1 ]
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT RADIOL,BOSTON,MA 02115
关键词
LIVER NEOPLASMS; MAGNETIC RESONANCE (MR); PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.189.2.8210368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of fast spin-echo (FSE) magnetic resonance imaging with and without fat suppression in the liver and upper abdomen. MATERIALS AND METHODS: Conventional spin-echo (SE) T2-weighted, FSE T2-weighted, and fat-suppressed FSE T2-weighted images from 37 patients strongly suspected to have focal hepatic lesions were evaluated. RESULTS: Quantitative analysis demonstrated that fat-suppressed FSE imaging had the highest lesion-liver contrast-to-noise ratio; conventional SE imaging, the lowest. In a qualitative analysis, FSE imaging was preferred. In a rank order analysis, FSE imaging was preferred 83% of the time and fat-suppressed FSE imaging 17% of the time as regards overall image quality; fat-suppressed FSE imaging was preferred 64% of the time, FSE imaging 23% of the time, and conventional SE imaging 13% of the time as regards signal abnormality detection. CONCLUSION: FSE imaging with and without fat suppression is a potentially useful pulse sequence for evaluating the upper abdomen.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 50 条
  • [1] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [2] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [3] Fat-suppressed T2-weighted MR imaging of hepatocellular carcinoma and metastases: Comparison of conventional spin-echo, fast spin-echo, and echoplanar pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Itoh, K
    Hori, M
    Inaba, Y
    Kondo, H
    Yokoyama, R
    Nakamura, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (01): : 25 - 32
  • [4] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184
  • [5] CONTRAST ON T2-WEIGHTED IMAGES OF THE LUMBAR SPINE USING FAST SPIN-ECHO AND GATED CONVENTIONAL SPIN-ECHO SEQUENCES
    CHAPPELL, PM
    GLOVER, GH
    ENZMANN, DR
    NEURORADIOLOGY, 1995, 37 (03) : 183 - 186
  • [6] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [7] FAST SPIN-ECHO IMAGING OF THE NECK - COMPARISON WITH CONVENTIONAL SPIN-ECHO, UTILITY OF FAT-SUPPRESSION, AND EVALUATION OF TISSUE CONTRAST CHARACTERISTICS
    LEWIN, JS
    CURTIN, HD
    ROSS, JS
    WEISSMAN, JL
    OBUCHOWSKI, NA
    TKACH, JA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (07) : 1351 - 1357
  • [8] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [9] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [10] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437