MAGNETIC-RESONANCE-IMAGING DURING DOBUTAMINE STRESS IN CORONARY-ARTERY DISEASE

被引:151
|
作者
PENNELL, DJ [1 ]
UNDERWOOD, SR [1 ]
MANZARA, CC [1 ]
SWANTON, RH [1 ]
WALKER, JM [1 ]
ELL, PJ [1 ]
LONGMORE, DB [1 ]
机构
[1] UNIV COLL & MIDDLESEX SCH MED,LONDON,ENGLAND
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1992年 / 70卷 / 01期
基金
英国医学研究理事会;
关键词
D O I
10.1016/0002-9149(92)91386-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cine magnetic resonance imaging (MRI) provides a tomographic method of assessing regional ventricular function in any desired plane. It has not been possible to obtain adequate images during dynamic exercise, and this has limited its value in patients with coronary artery disease (CAD). Therefore, an infusion of dobutamine was used to study 25 patients with exertional chest pain and abnormal exercise electrocardiograms. Areas of abnormal wall motion were compared with areas of abnormal myocardial perfusion imaged by dobutamine thallium emission tomography and with coronary arteriography. Twenty-two patients had significant CAD. Twenty-one (96%) of these patients had reversible myocardial ischemia shown by dobutamine thallium tomography, and 20 (91%) had reversible wall motion abnormalities shown by dobutamine MRI. Comparison of abnormal segments of perfusion and wall motion showed 96% agreement at rest, 90% agreement during stress, and 91% agreement for the assessment of functional reversibility. The normalized magnetic resonance signal intensity of the ischemic segments showed a small but significant reduction when compared with that of normal segments (-67 units [9.2%]; p <0.05). Dobutamine infusion was well-tolerated, despite causing chest discomfort in 24 patients (96%). Nine patients (36%) developed a minor dysrhythmia that was usually ventricular premature complexes, but this did not limit infusion, and other side effects were mild. The short plasma half-life of dobutamine makes it ideal as a stress agent for imaging techniques (such as MRI), and these results suggest that it is more effective in the provocation of wall motion abnormalities than is dipyridamole in patients with CAD.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [21] Value of additional myocardial perfusion imaging during dobutamine stress magnetic resonance for the assessment of intermediate coronary artery disease
    Rolf Gebker
    M. Frick
    C. Jahnke
    A. Berger
    C. Schneeweis
    R. Manka
    S. Kelle
    C. Klein
    B. Schnackenburg
    E. Fleck
    I. Paetsch
    The International Journal of Cardiovascular Imaging, 2012, 28 : 89 - 97
  • [22] ANOMALOUS AORTIC ORIGIN OF THE RIGHT CORONARY-ARTERY DETECTED BY MAGNETIC-RESONANCE-IMAGING
    FUNADA, J
    SUMIMOTO, T
    MATSUOKA, H
    HAMADA, M
    HIWADA, K
    JOURNAL OF CARDIOVASCULAR TECHNOLOGY, 1992, 10 (02): : 127 - 129
  • [23] THE ASSESSMENT OF CORONARY-ARTERY BYPASS GRAFTS BY MAGNETIC-RESONANCE-IMAGING WITH VELOCITY MAPPING
    UNDERWOOD, SR
    FIRMIN, DN
    KLIPSTEIN, RH
    REES, RSO
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1987, 57 (01): : 93 - 93
  • [24] NONINVASIVE EVALUATION OF THE LEFT MAIN CORONARY-ARTERY IN MAN WITH MAGNETIC-RESONANCE-IMAGING
    VERED, Z
    KENZORA, J
    GUTIERREZ, F
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1990, 4 (03): : 154 - 158
  • [25] COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY TO DOBUTAMINE SPECT ISONITRILE PERFUSION IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE
    STOLBER, TR
    SMART, SC
    HELLMAN, RS
    WYNSEN, JC
    SAGAR, KB
    CLINICAL RESEARCH, 1993, 41 (03): : A641 - A641
  • [26] COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY TO DOBUTAMINE SPECT ISONITRILE PERFUSION IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE
    STOLBER, TR
    SMART, SC
    HELLMAN, RS
    STAN, R
    WYNSEN, JC
    SAGAR, KB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A55 - A55
  • [27] MECHANISMS OF HYPOTENSION DURING DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    TANIMOTO, M
    PAI, RG
    JINTAPAKORN, W
    SHAH, PM
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (01): : 26 - 30
  • [28] MAGNETIC-RESONANCE CORONARY-ARTERY IMAGING
    PASCHAL, CB
    HAACKE, EM
    ADLER, LP
    FINELLI, DA
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (01) : 23 - 31
  • [29] DETECTION OF ANOMALOUS ORIGIN OF THE LEFT CORONARY-ARTERY BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND MAGNETIC-RESONANCE-IMAGING
    KAKU, B
    SHIMIZU, M
    KITA, Y
    YOSHIO, H
    INO, H
    TAKEDA, R
    JAPANESE HEART JOURNAL, 1994, 35 (03): : 383 - 388
  • [30] BRAIN MAGNETIC-RESONANCE-IMAGING IN CORONARY-ARTERY BYPASS GRAFTS - A PREOPERATIVE AND POSTOPERATIVE ASSESSMENT
    SCHMIDT, R
    FAZEKAS, F
    OFFENBACHER, H
    MACHLER, H
    FREIDL, W
    PAYER, F
    RIGLER, B
    HARRISON, MIG
    LECHNER, H
    NEUROLOGY, 1993, 43 (04) : 775 - 778