CALF BLOOD-FLOW AND POSTURE - DOPPLER ULTRASOUND CALIBRATED BY PLETHYSMOGRAPHY

被引:10
|
作者
VANLEEUWEN, BE
LUBBERS, J
BARENDSEN, GJ
DEPATER, L
机构
[1] Laboratorium voor Medische Fysica, 9712 KZ Groningen
关键词
RHYTHMIC MUSCLE CONTRACTIONS; CALF ERGOMETRY; EXERCISE HYPEREMIA;
D O I
10.1152/jappl.1992.72.5.1668
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A procedure was developed that enables measurement of rapid variations in calf blood flow during voluntary rhythmic contraction of the calf muscles in supine, sitting, and standing positions. During the exercise, maximum blood velocity is measured by Doppler ultrasound equipment in the popliteal artery. The Doppler signals are calibrated by plethysmography to enable calculation of blood flow during exercise in ml.100 ml-1.min-1. Knowledge of the cross-sectional area of the vessel and the angle of insonation is not required in this procedure. Evaluation of the calibration method with 10 healthy volunteers showed that for each subject a new calibration was necessary after a change in posture; the relationship between the blood flow and the maximum Doppler frequency averaged over one heart cycle was linear for each calibration.
引用
收藏
页码:1668 / 1674
页数:7
相关论文
共 50 条
  • [41] GRAVIMETRIC PLETHYSMOGRAPHY FOR MEASUREMENT OF BLOOD-FLOW IN THE LEG
    WIGGINS, PA
    LEVESON, SH
    KESTER, RC
    WILDE, DT
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1980, 4 (01) : 16 - 19
  • [42] FOREARM BLOOD-FLOW RESPONSE TO POSTURE CHANGE IN THE VERY OLD - NONINVASIVE MEASUREMENT BY VENOUS OCCLUSION PLETHYSMOGRAPHY
    LIPSITZ, LA
    BUI, M
    STIEBELING, M
    MCARDLE, C
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1991, 39 (01) : 53 - 59
  • [43] INFLUENCE OF POSTURE ON HEPATIC BLOOD-FLOW
    BUCHALI, K
    SCHIMMELPFENNIG, W
    SEST, C
    MALUSZEK, S
    SAPIA, C
    CORRENS, HJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1980, 5 (04): : 303 - 304
  • [44] DOPPLER ULTRASOUND ASSESSMENT OF CEREBRAL BLOOD-FLOW IN THE HUMAN-FETUS
    WLADIMIROFF, JW
    TONGE, HM
    STEWART, PA
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1986, 93 (05): : 471 - 475
  • [45] BLOOD-FLOW PATTERNS IN ESOPHAGEAL-VARICES MEASURED BY DOPPLER ULTRASOUND
    MCCORMACK, T
    MARTIN, T
    SMALLWOOD, RH
    ROBINSON, P
    WALTON, L
    JOHNSON, AG
    GUT, 1983, 24 (05) : A459 - A459
  • [46] THE MEASUREMENT OF BLOOD-FLOW PARAMETERS WITH THE AID OF ULTRASOUND PULSE DOPPLER TECHNIQUES
    GROSSMANN, H
    KLEMENZ, A
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1981, 36 (15): : 648 - 652
  • [47] DOPPLER ULTRASOUND PROBE FOR ASSESSMENT OF BLOOD-FLOW IN ESOPHAGEAL-VARICES
    MCCORMACK, T
    SMALLWOOD, RH
    WALTON, L
    MARTIN, T
    ROBINSON, P
    JOHNSON, AG
    LANCET, 1983, 1 (8326): : 677 - 678
  • [48] SPLENIC BLOOD-FLOW MEASUREMENTS BY DOPPLER ULTRASOUND - A PRELIMINARY-REPORT
    MANOHARAN, A
    GILL, RW
    GRIFFITHS, KA
    CARDIOVASCULAR RESEARCH, 1987, 21 (10) : 779 - 782
  • [49] BLOOD-FLOW IN CAROTID AND VERTEBRAL ARTERIES AT CHOKE HOLDS IN ULTRASOUND DOPPLER
    DENK, W
    HELMER, M
    MISSLIWETZ, J
    ZEITSCHRIFT FUR RECHTSMEDIZIN-JOURNAL OF LEGAL MEDICINE, 1990, 103 (05): : 369 - 377
  • [50] REPEATABILITY OF BLOOD-FLOW MEASUREMENT USING MULTICHANNEL PULSED DOPPLER ULTRASOUND
    STACEYCLEAR, A
    FISH, PJ
    BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (677): : 419 - 420