RESPONSE OF ELECTROCHEMICAL SENSORS TO IONIZING-RADIATION IN HIGH-TEMPERATURE AQUEOUS ENVIRONMENTS

被引:7
|
作者
TAYLOR, DF
机构
[1] GE Corporate Research and, Development, Schenectady, NY
关键词
AUTOCLAVE; BREMSSTRAHLUNG; BWR; CONDUCTIVITY; CORROSION POTENTIAL; DOSIMETRY; LINAC; PH; RADIOLYSIS; REFERENCE ELECTRODE; STAINLESS STEEL;
D O I
10.5006/1.3585226
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A high-energy electron linear accelerator (LINAC) generated intense electromagnetic bremsstrahlung that approximated the gamma dose rate in the core of a boiling water nuclear reactor (BWR). Experiments with polymer-free platinum, pH, and silver/ silver chloride electrodes at BWR operating temperatures in a stainless steel (SS) autoclave showed reversible, stable voltage offsets that depended on water chemistry and radiation intensity. These changes occurred slowly, and the potentials required several minutes to attain a steady state. Even with a remote reference, it is not possible to determine unequivocally the magnitude and direction of the shift for a specific electrode, but these measurements are most consistent with substantial (100 mV) offsets for silver/silver chloride electrodes, and relatively stable operation for zirconia-membrane pH electrodes. Radiation had no significant effect on high-temperature conductivity. Chemical interactions with radiolytic species offer the simplest explanation for the
引用
收藏
页码:115 / 122
页数:8
相关论文
共 50 条