POSITIVE DC CORONA AND SPARKOVER IN SHORT AND LONG ROD-PLANE GAPS UNDER VARIABLE HUMIDITY CONDITIONS

被引:17
|
作者
BOUTLENDJ, M [1 ]
ALLEN, NL [1 ]
LIGHTFOOT, HA [1 ]
NEVILLE, RB [1 ]
机构
[1] NAT GRID RES & DEV CTR,SURREY KT22 7ST,ENGLAND
来源
关键词
BREAKDOWN AND GAS DISCHARGES; DISCHARGES; GAS;
D O I
10.1049/ip-a-3.1991.0004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The variations, with humidity, of the positive DC corona-current voltage characteristics and of sparkover stresses have been studied in rod-plane gaps of spacings in the range 10 less-than-or-equal-to d less-than-or-equal-to 150 cm. The steady component of the current in the glow regime is described by the square law equation over the whole range of gaps, requiring only adjustment of a coefficient for each combination of gap spacing and humidity employed. The rate of change of current with humidity, at any constant voltage, is the same for all gap spacings. The mean stress for sparkover is the same for gaps 50 less-than-or-equal-to d less-than-or-equal-to 150 cm, irrespective of rod profile, and is linear with humidity variation, but anomalous low sparkover stresses occur above 19 g/m3 in the largest gaps. In shorter gaps, the rod profile plays a larger role, and the transition from glow-controlled to streamer-controlled breakdown is demonstrated in the 20 cm gap.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [21] Prediction of DC Corona Onset Voltage for Rod-Plane Air Gaps by a Support Vector Machine
    金硕
    阮江军
    杜志叶
    朱琳
    舒胜文
    Plasma Science and Technology, 2016, 18 (10) : 998 - 1004
  • [22] VARIATION OF CORONA INCEPTION AND SPARKOVER WITH POSITIVE IMPULSE VOLTAGE IN A ROD-PLANE GAP - EFFECT OF NEGATIVE SMALL ION VARIATION
    ALLEN, NL
    ALLIBONE, TE
    DRING, D
    JOURNAL DE PHYSIQUE, 1979, 40 : 423 - 424
  • [23] Computation of breakdown voltage of long rod-plane air gaps in large temperature and humidity range under positive standard switching impulse voltage
    Ge, Xing
    Ding, Yujian
    Yao, Xiuyuan
    Lv, Fangcheng
    Yang, Bingxue
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187
  • [24] Impulse Corona Inception in Dielectric Covered Rod-Plane Air Gaps
    Mavroidis, P. N.
    Mikropoulos, P. N.
    Stassinopoulos, C. A.
    UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 317 - 320
  • [25] The Impact of Composite AC-DC Voltage on Characteristics of Corona Discharge in Rod-plane Air Gaps
    Zhang, Jinglan
    Qi, Lei
    Lu, Tiebing
    Bian, Xingming
    Zhao, Zhibin
    Fu, Yuke
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 350 - 353
  • [26] Prediction study on positive DC corona onset voltage of rod-plane air gaps and its application to the design of valve hall fittings
    Qiu, Zhibin
    Ruan, Jiangjun
    Huang, Daochun
    Shu, Shengwen
    Du, Zhiye
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (07) : 1519 - 1526
  • [27] INFLUENCE OF HUMIDITY ON THE BREAKDOWN MECHANISM OF MEDIUM LENGTH ROD-PLANE GAPS STRESSED BY POSITIVE IMPULSE VOLTAGES
    MIKROPOULOS, PN
    STASSINOPOULOS, CA
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (05) : 407 - 417
  • [28] INFLUENCE OF HUMIDITY ON THE BREAKDOWN-MECHANISM OF SMALL ROD-PLANE GAPS STRESSED BY POSITIVE IMPULSE VOLTAGES
    STASSINOPOULOS, C
    ANDREADOU, K
    SERGAKI, A
    ETZ ARCHIV, 1990, 12 (09): : 273 - 278
  • [29] BREAKDOWN OF ROD-PLANE GAPS IN SF6 UNDER POSITIVE SWITCHING IMPULSES
    ANIS, H
    SRIVASTAVA, KD
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (03): : 537 - 546
  • [30] Positive switching impulse discharge performance of rod-plane short air gap under rain conditions
    Jiang Xingliang
    Xie Yanbin
    Yuan Yao
    Shu Lichun
    Zhang Zhijin
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (06) : 744 - 750