POSITIVE DC CORONA AND SPARKOVER IN SHORT AND LONG ROD-PLANE GAPS UNDER VARIABLE HUMIDITY CONDITIONS

被引:17
|
作者
BOUTLENDJ, M [1 ]
ALLEN, NL [1 ]
LIGHTFOOT, HA [1 ]
NEVILLE, RB [1 ]
机构
[1] NAT GRID RES & DEV CTR,SURREY KT22 7ST,ENGLAND
来源
关键词
BREAKDOWN AND GAS DISCHARGES; DISCHARGES; GAS;
D O I
10.1049/ip-a-3.1991.0004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The variations, with humidity, of the positive DC corona-current voltage characteristics and of sparkover stresses have been studied in rod-plane gaps of spacings in the range 10 less-than-or-equal-to d less-than-or-equal-to 150 cm. The steady component of the current in the glow regime is described by the square law equation over the whole range of gaps, requiring only adjustment of a coefficient for each combination of gap spacing and humidity employed. The rate of change of current with humidity, at any constant voltage, is the same for all gap spacings. The mean stress for sparkover is the same for gaps 50 less-than-or-equal-to d less-than-or-equal-to 150 cm, irrespective of rod profile, and is linear with humidity variation, but anomalous low sparkover stresses occur above 19 g/m3 in the largest gaps. In shorter gaps, the rod profile plays a larger role, and the transition from glow-controlled to streamer-controlled breakdown is demonstrated in the 20 cm gap.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [1] Impulse breakdown of short rod-plane gaps and the influence of humidity
    Mikropoulos, PN
    Stassinopoulos, CA
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1998, 145 (04) : 141 - 146
  • [2] EFFECT OF HUMIDITY AND TEMPERATURE ON THE DC BREAKDOWN OF ROD-ROD AND ROD-PLANE GAPS
    ABRAHAM, AP
    PRABHAKAR, BR
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (02): : 207 - 213
  • [3] Effect of Humidity on Corona Characteristics Under Rod-Plane Gap
    Wu, Dengjin
    Mei, Hongwei
    Shao, Tianying
    Wang, Liming
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 359 - 366
  • [4] DC Positive Discharge Performance of Rod-plane Short Air Gap Under Rain Conditions
    Jiang, Xingliang
    Yuan, Yao
    Bi, Maoqiang
    Du, Yong
    Ma, Jianguo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (01) : 104 - 111
  • [5] CORONA, BREAKDOWN AND HUMIDITY IN THE ROD-PLANE GAP
    ALLEN, NL
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1986, 133 (08): : 562 - 568
  • [6] Comparison of Positive Leader Propagation in Rod-Plane and Inverted Rod-Plane Gaps
    He, Hengxin
    He, Junjia
    Chen, Weijiang
    Xie, Shijun
    Xiang, Nianwen
    Chen, Jiahong
    Gu, Shanqiang
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (01) : 22 - 28
  • [7] Corona Charge Injection Prior to Sparkover in an Inversed Rod-Plane Gap Under Composite Voltages
    Meng, Xiaobo
    Chen, Changlong
    Wang, Liming
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (03) : 1442 - 1449
  • [8] Inception threshold conditions for positive dc corona in a rod-plane electrode at low atmospheric temperatures
    Yi, Yong
    Tang, Wenxi
    Chen, Zhengying
    Wang, Liming
    PHYSICS OF PLASMAS, 2017, 24 (10)
  • [9] Onset voltage of positive glow corona in rod-plane gaps as influenced by temperature
    Abdel-Salam, M
    Allen, NL
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2005, 152 (05) : 227 - 232
  • [10] Positive lightning breakdown characteristics of short rod-plane air gaps
    Mikropoulos, Pantelis N.
    Tsouris, Petros P.
    Chatzichristodoulou, Ioannis A.
    Binias, Konstantinos K.
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,