AUTOMATED DETECTION AND QUANTIFICATION OF RETINAL EXUDATES

被引:99
|
作者
PHILLIPS, R
FORRESTER, J
SHARP, P
机构
[1] UNIV ABERDEEN,SCH MED,DEPT OPHTHALMOL,ABERDEEN AB9 2ZD,SCOTLAND
[2] UNIV ABERDEEN,DEPT BIOMED PHYS,ABERDEEN AB9 2ZD,SCOTLAND
关键词
D O I
10.1007/BF00920219
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Retinal exudates are a common manifestation of vascular damage in a variety of retinal diseases. We have used computerized image analysis to detect and measure the area of exudates from digitized colour fundus slides of patients with diabetic retionpathy and have assessed the repeatability, reproducibility, and accuracy of the technique. The analysis was entirely independent of the operator apart from choice of the region to be analysed. The coefficient of variation for repeatability was between 3% for large areas of exudate and 17% for small areas of exudate. The reproducibility was also within this range. Sensitivity was between 61 and 100% (mean 87%). False-positives were observed in 5 of 30 regions analysed, and these could have been eliminated by using more stringent criteria for selection of images for analysis. Time taken for the analysis was approximately 3 min.
引用
收藏
页码:90 / 94
页数:5
相关论文
共 50 条
  • [41] Neural network based detection of hard exudates in retinal images
    Garcia, Maria
    Sanchez, Clara I.
    Lopez, Maria I.
    Abasolo, Daniel
    Hornero, Roberto
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 93 (01) : 9 - 19
  • [42] Exudates and optic disk detection in retinal images of diabetic patients
    Zeljkovic, Vesna
    Bojic, Milena
    Zhao, Shengwei
    Tameze, Claude
    Valev, Ventzeslav
    CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE, 2015, 27 (01): : 172 - 192
  • [43] Automatic Detection of Exudates in Retinal Images Using Histogram Analysis
    Kumar, Sharath P. N.
    Kumar, Rajesh R.
    Sathar, Anuja
    Sahasranamam, V
    2013 IEEE RECENT ADVANCES IN INTELLIGENT COMPUTATIONAL SYSTEMS (RAICS), 2013, : 277 - 281
  • [44] Automated detection of exudates and macula for grading of diabetic macular edema
    Akram, M. Usman
    Tariq, Anam
    Khan, Shoab A.
    JavedDepartment, M. Younus
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 114 (02) : 141 - 152
  • [45] A computer system for automated retinal microvascular architecture quantification
    Thom, SA
    Gao, X
    Stanton, AV
    Chapman, JN
    Bharath, A
    Hughes, AD
    JOURNAL OF HYPERTENSION, 1998, 16 : S106 - S106
  • [46] An Integrated System for Detection Exudates and Severity Quantification for Diabetic Macular Edema
    Thulkar, Dhanshree
    Daruwala, Rohin
    Sardar, Nikhil
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2020, 40 (06) : 798 - 820
  • [47] An Integrated System for Detection Exudates and Severity Quantification for Diabetic Macular Edema
    Dhanshree Thulkar
    Rohin Daruwala
    Nikhil Sardar
    Journal of Medical and Biological Engineering, 2020, 40 : 798 - 820
  • [48] Feature extraction and selection for the automatic detection of hard exudates in retinal images
    Garcia, Maria
    Hornero, Roberto
    Sanchez, Clara I.
    Lopez, Maria I.
    Diez, Ana
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4969 - +
  • [49] Exudates Detection Using Morphology Mean Shift Algorithm in Retinal Images
    Wisaeng, Kittipol
    Sa-Ngiamvibool, Worawat
    IEEE ACCESS, 2019, 7 : 11946 - 11958
  • [50] Retinal exudates detection algorithm by fusing reconstruction filters and dark features
    Lai, Xiao-Bo
    Liu, Hua-Shan
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2013, 24 (06): : 1238 - 1244