AUTOMATIC KINETIC METHOD FOR THE DETERMINATION OF REDUCED GLUTATHIONE IN BLOOD

被引:6
|
作者
JIMENEZPRIETO, R [1 ]
VELASCO, A [1 ]
SILVA, M [1 ]
PEREZBENDITO, D [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
KINETIC METHODS; UV VISIBLE SPECTROPHOTOMETRY; BLOOD; REDUCED GLUTATHIONE;
D O I
10.1016/0003-2670(92)85413-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple kinetic method is reported for the determination of reduced glutathione (GSH) by the continuous addition of reagent technique that is suitable for routine analyses in blood samples. The method is based on the oxidation reaction between GSH and copper(II) in a weakly acidic medium in the presence of neocuproin to form the coloured copper(I)-neocuproin complex, the rate of formation of which is monitored spectrophotometrically. Two kinetic methodologies were tested for the determination of GSH. The calibration graph was linear over a wide range, 1.6 x 10(-6)-1.6 x 10(-4) M (R.S.D. almost-equal-to 2%), and the method is fairly selective and offers several advantanges over the classical 5,5'-dithiobis(2-nitrobenzoic acid) method for the routine determination of GSH in blood samples, namely ease of automation, faster sample throughout and no need for a blank.
引用
收藏
页码:273 / 279
页数:7
相关论文
共 50 条
  • [31] An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes
    Loughlin, AF
    Skiles, GL
    Alberts, DW
    Schaefer, WH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (01) : 131 - 142
  • [32] Determination of lead in blood by the kinetic differential potentiometric stripping method
    Xie, Weiping
    Hu, Guilian
    Huang, Yingyu
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2000, 36 (07): : 307 - 308
  • [33] Electrocatalytic determination of reduced glutathione in human erythrocytes
    Rita de Cássia Silva Luz
    Flavio Santos Damos
    Paulo Guimarães Gandra
    Denise Vaz de Macedo
    Auro Atsushi Tanaka
    Lauro Tatsuo Kubota
    Analytical and Bioanalytical Chemistry, 2007, 387 : 1891 - 1897
  • [34] Electrocatalytic determination of reduced glutathione in human erythrocytes
    Silva Luz, Rita de Cassia
    Damos, Flavio Santos
    Gandra, Paulo Guimaraes
    de Macedo, Denise Vaz
    Tanaka, Auro Atsushi
    Kubota, Lauro Tatsuo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) : 1891 - 1897
  • [35] Influence of vagotonia on the content of blood in reduced glutathione
    Zunz, E
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1932, 110 : 93 - 95
  • [36] Blood selenium, reduced glutathione and glutathione peroxidase in patients with liver cirrhosis
    Halota, W
    Staubach-Topczewska, E
    Czuczejko, J
    Zachara, BA
    MICROELEMENTS AND TRACE ELEMENTS, 1998, : 506 - 514
  • [37] Method of Electrochemical Determination of Glutathione
    Wang Jianguo
    Lue Hui
    Sun Qiaohua
    Li Rongzhi
    Zhong Yan
    Zhao Jian
    Liu Min
    Jia Xiang
    ACTA CHIMICA SINICA, 2009, 67 (05) : 415 - 419
  • [38] NITROPRUSSIDE METHOD FOR BLOOD GLUTATHIONE
    WATSON, D
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1964, 16 (05): : 587 - &
  • [39] THE DETERMINATION OF BLOOD GLUTATHIONE BY AMPEROMETRIC TITRATION
    BIDMEAD, DS
    WATSON, D
    JOURNAL OF CLINICAL PATHOLOGY, 1952, 5 (01) : 30 - 35
  • [40] KINETIC ENZYMATIC METHOD FOR AUTOMATED-DETERMINATION OF GLUCOSE IN BLOOD AND SERUM
    ZIEGENHORN, J
    NEUMANN, U
    HAGEN, A
    BABLOK, W
    STINSHOFF, K
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1977, 15 (01): : 13 - 19