Signal Analysis of Eddy Current Array Probe According to Size Variation of FBH Defects

被引:0
|
作者
Kim, Ji-Ho [1 ]
Lim, Geon-Gyu [1 ]
Lee, Hyang-Beom [1 ]
机构
[1] Soongsil Univ, Dept Elect Engn, Seoul 156743, South Korea
关键词
Eddy Current Testing (ECT); Steam Generator (SG) Tube; EC Array Probe; Finite Element Method;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, the signal analysis of eddy current array probe was performed to analyze the electromagnetic characteristics with the variation of FBH(flat bottomed hole) defects size on steam generator tube in NPP( nuclear power plants) using the electromagnetic finite element method. To obtain the electromagnetic characteristic of probes, the governing equation was derived from Maxwell's equations, and the individual problem was analyzed by using the 3-dimensional finite element method. For the simulation FBH defects were used. The depth of FBH defects were 20%, 40%, 60%, 80% and 100% of steam generator(SG) tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequencies of 100 kHz, 300 kHz and 400 kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the size variation of depth of FBH defects and operation frequencies. The results in this paper can be helpful when the ECT(eddy current testing) signals from EC array probe are evaluated and analyzed.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [21] Numerical analysis of eddy current testing probe
    Tsuboi, H
    Ikeda, K
    Kobayashi, F
    Misaki, T
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION, 1997, 12 : 67 - 72
  • [22] A remote field eddy current probe for outside inspection of pipe defects
    Xu, Zhiyuan
    Lin, Zhangpeng
    Xiao, Qi
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 59 (04) : 1543 - 1551
  • [23] A novel magnetic force transmission eddy current array probe and its application for nondestructive testing of defects in pipeline structures
    Xie, Shejuan
    Duan, Zhirong
    Li, Ji
    Tong, Zongfei
    Tian, Mingming
    Chen, Zhenmao
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 309
  • [24] Eddy Current Array Probe for Flaw Characterization of Zircoloy Fuel Rods
    Krzywosz, Kenji J.
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XII), 2009, 32 : 9 - 17
  • [25] Development of a flexible cross-wound eddy current array probe
    Lepage, Benoit
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 633 - 638
  • [26] Study on Signal Processing in Eddy Current Testing for Defects in Spline Gear
    Lee, Jae Ho
    Park, Tae Sung
    Park, Ik Keun
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2016, 36 (03) : 195 - 201
  • [27] Design and Analysis of a GMR Eddy Current probe for NDT
    Porto, R. W.
    Brusamarello, V. J.
    Azambuja, R.
    Frison, O., Jr.
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 424 - 429
  • [28] Detection and evaluation of subsurface defects using pulse eddy current differential probe
    Slobodnk, Karel
    PROCEEDINGS OF 2017 18TH INTERNATIONAL CONFERENCE ON COMPUTATIONAL PROBLEMS OF ELECTRICAL ENGINEERING (CPEE), 2017,
  • [29] Study for the Design of an Eddy Current Array Probe for the Imaging of Aeronautical Fastener Holes
    Thomas, Vincent
    Joubert, Pierre-Yves
    Vourc'h, Eric
    SENSOR LETTERS, 2009, 7 (03) : 460 - 465
  • [30] GMR array uniform eddy current probe for defect detection in conductive specimens
    Postolache, Octavian
    Ribeiro, Artur Lopes
    Geirinhas Ramos, H.
    MEASUREMENT, 2013, 46 (10) : 4369 - 4378