CLINICAL-EVALUATION OF A NEW DIGITAL CHEST IMAGING-SYSTEM

被引:7
|
作者
VANHEESEWIJK, JPM
DEVALOIS, JC
机构
[1] Department of Diagnostic Radiology, St. Antonius Hospital, Nieuwegein, NL-3435 CM
关键词
RADIOGRAPHY; DIGITAL; LUNG; THORAX; TECHNOLOGY;
D O I
10.1007/BF00178086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A digital chest imaging system based on a selenium detector has been installed in a large teaching hospital. Up to 1 May 1994, 7000 patients have been studied by this new technique. Hard copies are printed on a laser imager. Image quality of the digital system was analysed by day-to-day comparison with a conventional chest system. In a pilot study of 40 patients conventional and digital images were compared by analysing six different anatomical regions. Two readers judged the image quality of the digital system to be better than that of a conventional chest system, all regions being better visualised on the digital images (P < 0.01). Acceptance of the digital chest system by radiographers, radiologists and other medical specialists is good. More than half of the normal patient load is routinely dealt with using the new system. Retakes were hardly necessary. Post-processing is possible, but was seldom used, These preliminary overall results of a digital chest imaging system based on a selenium detector in routine clinical practice are promising and further phantom studies and clinical studies using receiver operating characteristic (ROC) analysis are currently being performed.
引用
下载
收藏
页码:83 / 87
页数:5
相关论文
共 50 条
  • [21] DIGITAL RECURSIVE FILTER FOR A PYROVIDICON THERMAL IMAGING-SYSTEM
    DEMESH, OV
    VLASENKO, SG
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1990, 57 (01): : 14 - 17
  • [22] DIGITAL SYNTHETIC FOCUS ACOUSTIC IMAGING-SYSTEM FOR NDE
    CORL, PD
    GRANT, PM
    KINO, GS
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1979, 26 (02): : 179 - 179
  • [23] DEVELOPMENT OF NEW IMAGING-SYSTEM FOR CHEST RADIOGRAPHY - INVESTIGATION OF BASIC IMAGING PROPERTIES AND IMPROVEMENT OF SIGNAL-DETECTION
    HIGASHIDA, Y
    KARIYA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (9A): : 2139 - 2143
  • [24] CLINICAL-EVALUATION OF A NEW DEVICE FOR DIGITAL AMBULATORY ESOPHAGEAL MOTILITY MONITORING
    JOELSSON, B
    ESSENMOLLER, A
    DEMEESTER, TR
    GASTROENTEROLOGY, 1986, 90 (05) : 1478 - 1478
  • [25] CLINICAL-EVALUATION OF POSITIVE MYOCARDIAL IMAGING
    HALE, TI
    JUCKER, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (11): : 525 - 526
  • [26] NMR IMAGING - A PRELIMINARY CLINICAL-EVALUATION
    HOLLAND, GN
    HAWKES, RC
    MOORE, WS
    WORTHINGTON, BS
    NEURORADIOLOGY, 1980, 20 (05) : 277 - 277
  • [27] CONSIDERATIONS IN THE COMMISSIONING OF AN NMR CLINICAL IMAGING-SYSTEM
    MORGAN, TJ
    WILLCOTT, R
    MEDICAL PHYSICS, 1983, 10 (04) : 551 - 551
  • [28] LOCOMOTOR SYSTEM - CLINICAL-EVALUATION
    LAFLAMME, GH
    GUIMOND, A
    GRENIER, R
    MATHON, G
    MESSELY, MC
    SHIELDS, J
    UNION MEDICALE DU CANADA, 1980, 109 (04): : 507 - &
  • [29] CLINICAL-EVALUATION OF NEW MEDICATIONS
    LEWIS, PJ
    REVUE DU PRATICIEN, 1982, 32 (41-4): : 2649 - &
  • [30] CLINICAL-EVALUATION OF THE MASTER ROBOT SYSTEM AND DEVELOPMENT OF A NEW VERSION
    CAMMOUN, R
    DETRICHE, JM
    LAUTURE, F
    LESIGNE, B
    ROBOTICA, 1993, 11 : 535 - 539