COMPUTERIZED ANALYSIS OF FETAL HEART-RATE .1. DESCRIPTION OF THE SYSTEM (2CTG)

被引:0
|
作者
ARDUINI, D
RIZZO, G
PIANA, G
BONALUMI, A
BRAMBILLA, P
ROMANINI, C
机构
来源
关键词
FETAL HEART RATE; ACCELERATIONS; DECELERATIONS; COMPUTER; AUTOMATIC ANALYSIS; FETAL BEHAVIOR;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The object of this study was to develop an automatic system for the on-line analysis of fetal heart rate based on a low cost personal computer and allowing a reliable identification of both baseline and fetal heart rate patterns. Methods: An on-line method of baseline identification has been constructed on the implementation of the off-line method described by Mantel et al.6 Based on the determination of the baseline, accelerations and decelerations were identified, short- and long-term variability indices were measured, and fetal heart rate patterns (A to D) were identified. The results of the baseline fitting were evaluated on 20 tracings lasting 2 h. The on-line method developed was compared with the original off-line method by considering the agreement of a panel of five experts on baseline fitting and by regression analysis between the absolute values of baseline obtained. Tracings (169) lasting greater-than-or-equal-to 60 min from uneventful pregnancies at 31-42 weeks' gestation were also evaluated and the relationships between the fetal heart parameters were measured and both gestational age and fetal heart rate patterns were analyzed. Results: The panel of experts judged that in 70% of the cases, both methods fitted the baseline in an equivalent way. In the remaining 30% of the cases, experts frequently disagreed on considering the best fitting methods. Regression analysis showed a high coefficient of correlation (r = 0.92, P less-than-or-equal-to 0.001) between the baseline estimation of the two methods, with a maximum difference in baseline values of 4 beats per min (bpm) (median 2 bpm). Significant changes of baseline and the number and amplitude of accelerations were evidenced with advancing gestation. Significantly lower values of fetal heart variability were found during fetal heart rate pattern A when compared with pattern B. Conclusions: The automatic system of fetal heart analysis developed provides a reliable on-line identification of the baseline, a detection of accelerations and decelerations, and a measurement of fetal heart rate variability. Finally, by identifying the fetal heart rate patterns, it allows the study of fetal heart rate variability in relation to fetal behavior, a tool that may further validate this technique.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [41] Impact of CTG-stickers on fetal heart rate pattern analysis
    Nizard, Jacky
    Eid, Julia
    du Moncel, Sophie Tezenas
    Buzenet, Christine
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S300 - S300
  • [42] Improvements in computerized fetal heart rate analysis antepartum
    Dawes, GS
    Moulden, M
    Redman, CWG
    JOURNAL OF PERINATAL MEDICINE, 1996, 24 (01) : 25 - 36
  • [43] FETAL HEART-RATE RECORDING AND ANALYSIS DURING PREGNANCY
    MURRILLS, AJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (01): : 169 - 169
  • [44] POWER SPECTRAL-ANALYSIS OF FETAL HEART-RATE
    OPPENHEIMER, LW
    LEWINSKY, RM
    BAILLIERES CLINICAL OBSTETRICS AND GYNAECOLOGY, 1994, 8 (03): : 643 - 661
  • [45] CRITERIA FOR THE DESIGN OF FETAL HEART-RATE ANALYSIS SYSTEMS
    DAWES, GS
    MOULDEN, M
    REDMAN, CWG
    INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1990, 25 (04): : 287 - 294
  • [46] ANALYSIS OF HEART-RATE PATTERNS PRECEDING FETAL DEATH
    GAZIANO, EP
    FREEMAN, DW
    OBSTETRICS AND GYNECOLOGY, 1977, 50 (05): : 578 - 582
  • [47] SYSTEM FUNCTION BETWEEN BREATHING RATE AND HEART-RATE IN FETAL SHEEP
    NOGUCHI, Y
    DWYER, G
    SZETO, HH
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 731 - 732
  • [48] Fetal gastroschisis: antepartum fetal heart rate analysis by computerized cardiotocography
    Andrade, Walkyria S.
    Brizot, Maria de L.
    Miyadahira, Seizo
    Osmundo Junior, Gilmar de Souza
    Francisco, Rossana P. V.
    Zugaib, Marcelo
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2017, 30 (05): : 605 - 611
  • [49] Automatic Deceleration Detection System from Fetal Heart Rate obtained by CTG
    Yamamoto, Hiroko
    Mitsukura, Yasue
    2022 IEEE 17TH INTERNATIONAL CONFERENCE ON ADVANCED MOTION CONTROL (AMC), 2022, : 346 - 351
  • [50] INTRAPARTUM FETAL HEART-RATE MONITORING .5. FETAL HEART-RATE PATTERNS IN THE 2ND STAGE OF LABOR
    KREBS, HB
    PETRES, RE
    DUNN, LJ
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 140 (04) : 435 - 439