EXCIMER-LASER ABLATION OF NOVEL TRIAZENE POLYMERS - INFLUENCE OF STRUCTURAL PARAMETERS ON THE ABLATION CHARACTERISTICS

被引:76
|
作者
LIPPERT, T
STEBANI, J
IHLEMANN, J
NUYKEN, O
WOKAUN, A
机构
[1] UNIV BAYREUTH,D-95440 BAYREUTH,GERMANY
[2] LASER LAB GOTTINGEN,D-37016 GOTTINGEN,GERMANY
来源
JOURNAL OF PHYSICAL CHEMISTRY | 1993年 / 97卷 / 47期
关键词
D O I
10.1021/j100149a033
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Novel photopolymers based on the triazene chromophoric group have been developed. Structuring by XeCl* excimer laser irradiation at 308 nm results in ablation craters with clean contours and sharp edges; diffraction-limited resolution of almost-equal-to 0.4 mum is achieved. A prominent feature of the triazene polymers is the complete absence of solid debris around the edges of the ablation craters, which makes these materials attractive for applications in microelectronics. The dependence of the ablated depth per pulse on laser fluence is investigated and is related to the effective absorption coefficient and the quantum yield of photochemical decompostion of the polymers insolution. Other physicochemical and thermomechanical parameters of the polymers appear to be less influential on the ablation characteristics. The high fluence limit d(max) of the etch rate per pulse is found in the range between 2 and 3 mum for all investigated materials. On exposure to several high fluence laser pulses, an ejection of material has been observed from areas that are considerably larger than the incident laser beam. This effect may be due to either an explosive event or the generation of shock waves reflected at the sample substrate.
引用
收藏
页码:12296 / 12301
页数:6
相关论文
共 50 条
  • [31] EFFECT OF DEPTH UPON THE SMOOTHNESS OF EXCIMER-LASER CORNEAL ABLATION
    TAYLOR, SM
    FIELDS, CR
    BARKER, FM
    SANZO, J
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (02) : 104 - 108
  • [32] ACOUSTIC INSITU MONITORING OF EXCIMER-LASER ABLATION OF DIFFERENT CERAMICS
    GRAD, L
    MOZINA, J
    APPLIED SURFACE SCIENCE, 1993, 69 (1-4) : 370 - 375
  • [33] DEPOSITION OF TUNGSTEN FILMS BY PULSED EXCIMER-LASER ABLATION TECHNIQUE
    DHOTE, AM
    OGALE, SB
    APPLIED PHYSICS LETTERS, 1994, 64 (21) : 2809 - 2811
  • [34] DIFFRACTIVE SMOOTHING OF EXCIMER-LASER ABLATION USING A DEFOCUSED BEAM
    KRUEGER, RR
    WANG, XW
    RUDISILL, M
    TROKEL, SL
    MCDONNELL, PJ
    JOURNAL OF REFRACTIVE AND CORNEAL SURGERY, 1994, 10 (01): : 20 - 26
  • [35] POLYMER ABLATION WITH A HIGH-POWER EXCIMER-LASER TOOL
    WOLBOLD, GE
    TESSLER, CL
    TUDRYN, DJ
    MICROELECTRONIC ENGINEERING, 1993, 20 (1-2) : 3 - 14
  • [36] THE ORIGIN OF CENTRAL ISLANDS FOLLOWING EXCIMER-LASER PHOTO ABLATION
    EIFERMAN, RA
    LAMB, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S715 - S715
  • [37] EFFECT OF CORNEAL EDEMA UPON THE SMOOTHNESS OF EXCIMER-LASER ABLATION
    FIELDS, CR
    TAYLOR, SM
    BARKER, FM
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (02) : 109 - 114
  • [38] DAMAGE MECHANISMS FOR 193NM EXCIMER-LASER CORNEAL ABLATION
    MANSTEIN, D
    FORSTER, W
    SCHURENBERG, M
    HILLENKAMP, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2012 - 2012
  • [39] ATYPICAL CHARACTERISTICS OF KRF EXCIMER-LASER ABLATION OF INDIUM-TIN OXIDE-FILMS
    SZORENYI, T
    KANTOR, Z
    LAUDE, LD
    APPLIED SURFACE SCIENCE, 1995, 86 (1-4) : 219 - 222
  • [40] ABLATIAN PLUME PARTICLE DYNAMICS DURING EXCIMER-LASER ABLATION OF POLYIMIDE
    HAHN, DW
    EDIGER, MN
    PETTIT, GH
    JOURNAL OF APPLIED PHYSICS, 1995, 77 (06) : 2759 - 2766