Invading of intrauterine contraceptive device into the sigmoid colon through uterine perforation caused by a blunt trauma

被引:2
|
作者
Davoodabadi, Abdoulhossein [1 ]
Mohammadzadeh, Mahdi [1 ]
Amirbeigi, Mahdieh [1 ]
Jazayeri, Hoda [1 ]
机构
[1] Kashan Univ Med Sci, Trauma Res Ctr, Kashan, Iran
关键词
Intrauterine devices; Uterine perforation; Colon; Sigmoid;
D O I
10.1016/j.cjtee.2015.09.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intrauterine contraceptive device (IUCD) is relatively safe but still with some serious risks. Uterus perforation is rare and would be fatal. A case of Cu-7 IUCD invading into the sigmoid colon through uterine perforation caused by a pelvic blunt trauma was presented. Our case showed that uterus perforation by an IUCD could induce utero-sigmoid fistula which is likely to be missed. Imaging is required when the patients with IUCD present abdominal pain, particularly with a history of trauma. (C) 2015 Production and hosting by Elsevier B.V. on behalf of Daping Hospital and the Research Institute of Surgery of the Third Military Medical University.
引用
收藏
页码:235 / 237
页数:3
相关论文
共 50 条
  • [21] Case report -: Migration of an intrauterine contraceptive device to the sigmoid colon:: a case report
    Inceboz, ÜS
    Özçakir, HT
    Çaglar, H
    [J]. EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2003, 8 (04): : 229 - 232
  • [22] Appendix perforation by an intrauterine contraceptive device
    Ohana, E
    Sheiner, E
    Leron, E
    Mazor, M
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2000, 88 (02): : 129 - 131
  • [23] BOWEL PERFORATION BY AN INTRAUTERINE CONTRACEPTIVE DEVICE
    COHEN, PL
    SUTCLIFFE, TJ
    [J]. SOUTH AFRICAN MEDICAL JOURNAL, 1982, 62 (26): : 973 - 973
  • [24] Ureteral and sigmoid obstruction caused by pelvic actinomycosis in an intrauterine contraceptive device user
    Nasu, K
    Matsumoto, H
    Yoshimatsu, J
    Miyakawa, I
    [J]. GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2002, 54 (04) : 228 - 231
  • [25] Perforation of the colon after blunt trauma
    Barden, BE
    Maull, KI
    [J]. SOUTHERN MEDICAL JOURNAL, 2000, 93 (01) : 33 - 35
  • [26] RECOVERY OF THE INTRAUTERINE CONTRACEPTIVE DEVICE FROM THE SIGMOID COLON - 3 CASE-REPORTS
    BROWNING, JJ
    BIGRIGG, MA
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1988, 95 (05): : 530 - 532
  • [27] THE INTRAUTERINE-DEVICE AND UTERINE PERFORATION
    SIVIN, I
    [J]. OBSTETRICS AND GYNECOLOGY, 1984, 64 (05): : 744 - 745
  • [29] Perforation of uterus by the GyneFix intrauterine contraceptive device
    Al-Kamil, RK
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2000, 54 (02) : 128 - 129
  • [30] ACCIDENTAL PERFORATION OF UTERUS WITH AN INTRAUTERINE CONTRACEPTIVE DEVICE
    COOKE, BJE
    [J]. BRITISH MEDICAL JOURNAL, 1966, 1 (5497): : 1236 - &