NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT BY ARTERIAL TONOMETRY DURING ANESTHESIA IN CHILDREN

被引:31
|
作者
KEMMOTSU, O
OHNO, M
TAKITA, K
SUGIMOTO, H
OTSUKA, H
MORIMOTO, Y
MAYUMI, T
机构
[1] Anesthesiology/Intensive Care Dept., Hokkaido Univ. School of Medicine, Kita-ku
关键词
ANESTHESIA; PEDIATRIC; BLOOD PRESSURE; MEASUREMENT; TONOMETRY; MEASUREMENT TECHNIQUES;
D O I
10.1097/00000542-199411000-00009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The authors' previous study of arterial tonometry in children demonstrated poor agreement of tonometric blood pressure (TBP) measurements with intraarterial blood pressure (TBP) measurements. The aim of the current study is to evaluate the feasibility of TBP measurements in children aged 1-6 yr using a newly designed pediatric sensor housing, by comparing TBP values with values obtained by IBP measurements. Methods: Thirty-four children (aged 1-6 yr, ASA physical status 1-2) were studied undergoing elective abdominal or urologic surgery under general anesthesia. A 22- or 24-G cannula was inserted into the right radial artery. A TBP sensor housing was positioned over the left radial artery. TBP and IBP were continuously monitored and data were periodically sampled during and after intubation, during surgery, and during the recovery period. Results: TBP waveforms were similar to those of IBP. Limits of agreement (bias +/- 2 SD) were 12 and -13.3 mmHg for systolic, 11.6 and -10.4 mmHg for mean, and 13.2 and -10.8 mmHg for diastolic pressures for 3,400 paired points. Measurements could not be made in ten children because of insufficient pulse contour. Conclusions: When pulse contour is sufficient for analysis, TBP monitoring provides an apparently safe and accurate method for the continuous measurement of arterial blood pressure during anesthesia in children aged 1-6 yr.
引用
收藏
页码:1162 / 1168
页数:7
相关论文
共 50 条
  • [21] CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING BY RADIAL ARTERY TONOMETRY IN HIGH-RISK PATIENTS
    WEISS, BM
    RAHMIG, H
    SPAHN, DR
    ROHLING, R
    PASCH, T
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 9 - 9
  • [22] ACCURACY OF CONTINUOUS NONINVASIVE BLOOD-PRESSURE MEASUREMENT AT HIGH AND LOW BLOOD PRESSURES
    WONG, DH
    EATON, S
    CLACK, S
    ZACCARI, J
    SURESH, K
    BOGARD, D
    WATSON, TB
    [J]. ANESTHESIA AND ANALGESIA, 1994, 78 (02): : U257 - U257
  • [23] Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery
    Tanioku, Tadashi
    Yoshida, Akari
    Aratani, Yuichi
    Fujii, Keisuke
    Kawamata, Tomoyuki
    [J]. BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [24] Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery
    Tadashi Tanioku
    Akari Yoshida
    Yuichi Aratani
    Keisuke Fujii
    Tomoyuki Kawamata
    [J]. BMC Anesthesiology, 20
  • [25] MEASUREMENT OF ARTERIAL BLOOD-PRESSURE
    BEILIN, LJ
    JUELJENS.BE
    [J]. LANCET, 1972, 2 (7773): : 384 - &
  • [26] ARTERIAL BLOOD-PRESSURE MEASUREMENT
    WALLING, PT
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (01) : 122 - 122
  • [27] ARTERIAL BLOOD-PRESSURE MEASUREMENT
    HULL, CJ
    [J]. LANCET, 1972, 1 (7765): : 1399 - &
  • [28] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN THE NEONATE
    DARNALL, RA
    [J]. CLINICS IN PERINATOLOGY, 1985, 12 (01) : 31 - 49
  • [29] CONTINUOUS, SIMULTANEOUS MEASUREMENT OF ARTERIAL OXYGEN-TENSION AND ARTERIAL BLOOD-PRESSURE
    GOLD, MI
    DUARTE, I
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1975, 70 (04): : 656 - 660
  • [30] NONINVASIVE MEASUREMENT OF ARTERIAL BLOOD-PRESSURE IN DOGS - A POTENTIAL INDICATOR FOR THE IDENTIFICATION OF STRESS
    VINCENT, IC
    MICHELL, AR
    LEAHY, RA
    [J]. RESEARCH IN VETERINARY SCIENCE, 1993, 54 (02) : 195 - 201