NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT BY ARTERIAL TONOMETRY DURING ANESTHESIA IN CHILDREN

被引:31
|
作者
KEMMOTSU, O
OHNO, M
TAKITA, K
SUGIMOTO, H
OTSUKA, H
MORIMOTO, Y
MAYUMI, T
机构
[1] Anesthesiology/Intensive Care Dept., Hokkaido Univ. School of Medicine, Kita-ku
关键词
ANESTHESIA; PEDIATRIC; BLOOD PRESSURE; MEASUREMENT; TONOMETRY; MEASUREMENT TECHNIQUES;
D O I
10.1097/00000542-199411000-00009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The authors' previous study of arterial tonometry in children demonstrated poor agreement of tonometric blood pressure (TBP) measurements with intraarterial blood pressure (TBP) measurements. The aim of the current study is to evaluate the feasibility of TBP measurements in children aged 1-6 yr using a newly designed pediatric sensor housing, by comparing TBP values with values obtained by IBP measurements. Methods: Thirty-four children (aged 1-6 yr, ASA physical status 1-2) were studied undergoing elective abdominal or urologic surgery under general anesthesia. A 22- or 24-G cannula was inserted into the right radial artery. A TBP sensor housing was positioned over the left radial artery. TBP and IBP were continuously monitored and data were periodically sampled during and after intubation, during surgery, and during the recovery period. Results: TBP waveforms were similar to those of IBP. Limits of agreement (bias +/- 2 SD) were 12 and -13.3 mmHg for systolic, 11.6 and -10.4 mmHg for mean, and 13.2 and -10.8 mmHg for diastolic pressures for 3,400 paired points. Measurements could not be made in ten children because of insufficient pulse contour. Conclusions: When pulse contour is sufficient for analysis, TBP monitoring provides an apparently safe and accurate method for the continuous measurement of arterial blood pressure during anesthesia in children aged 1-6 yr.
引用
收藏
页码:1162 / 1168
页数:7
相关论文
共 50 条
  • [1] NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT BY ARTERIAL TONOMETRY DURING PEDIATRIC ANESTHESIA
    OHNO, M
    OHTSUKA, K
    UEDA, M
    KEMMOTSU, O
    [J]. ANESTHESIA AND ANALGESIA, 1993, 76 (02): : S308 - S308
  • [2] ARTERIAL TONOMETRY FOR NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MONITORING DURING ANESTHESIA
    KEMMOTSU, O
    UEDA, M
    OTSUKA, H
    YAMAMURA, T
    WINTER, DC
    ECKERLE, JS
    [J]. ANESTHESIOLOGY, 1991, 75 (02) : 333 - 340
  • [3] ARTERIAL TONOMETRY FOR CONTINUOUS RELATIVE BLOOD-PRESSURE MEASUREMENT
    ECKERLE, JS
    WARD, MM
    MONTGOMERY, LD
    PODLESNY, JA
    [J]. PSYCHOPHYSIOLOGY, 1984, 21 (05) : 575 - 576
  • [4] MEASUREMENT OF ARTERIAL BLOOD-PRESSURE DURING ANESTHESIA
    STAFFORD, MA
    BATCHELOR, AM
    [J]. BRITISH JOURNAL OF HOSPITAL MEDICINE, 1992, 47 (07) : 533 - 536
  • [5] ARTERIAL TONOMETRY FOR BLOOD-PRESSURE MONITORING IN GERIATRIC ANESTHESIA
    HARASAWA, K
    KEMMOTSU, O
    HOJO, Y
    OZAKI, S
    OHNO, M
    [J]. ANESTHESIOLOGY, 1993, 79 (3A) : A505 - A505
  • [6] BLOOD-PRESSURE MEASUREMENT BY ARTERIAL TONOMETRY IN CONTROLLED HYPOTENSION
    KEMMOTSU, O
    UEDA, M
    OTSUKA, H
    YAMAMURA, T
    OKAMURA, A
    ISHIKAWA, T
    WINTER, DC
    ECKERLE, JS
    [J]. ANESTHESIA AND ANALGESIA, 1991, 73 (01): : 54 - 58
  • [7] ACCURACY OF A CONTINUOUS BLOOD-PRESSURE MONITOR BASED ON ARTERIAL TONOMETRY
    SATO, T
    NISHINAGA, M
    KAWAMOTO, A
    OZAWA, T
    TAKATSUJI, H
    [J]. HYPERTENSION, 1993, 21 (06) : 866 - 874
  • [8] NONINVASIVE, CONTINUOUS BLOOD-PRESSURE MEASUREMENT IN PSYCHOPHYSIOLOGY
    GODAERT, G
    KRUITWAGEN, J
    JASPERS, J
    [J]. PSYCHOPHYSIOLOGY, 1985, 22 (05) : 591 - 592
  • [9] CONTINUOUS NONINVASIVE MONITORING OF ARTERIAL BLOOD-PRESSURE IN THE EMERGENCY DEPARTMENT
    KURKI, TS
    [J]. AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (02): : 103 - 105
  • [10] CONTINUOUS NONINVASIVE FINGER BLOOD-PRESSURE MONITORING IN CHILDREN
    TANAKA, H
    THULESIUS, O
    YAMAGUCHI, H
    MINO, M
    KONISHI, K
    [J]. ACTA PAEDIATRICA, 1994, 83 (06) : 646 - 652