Pulse Oximeter with Internet Data Visualization

被引:1
|
作者
Contreras Mota, Gabriel [1 ]
Lemuz Lopez, Rafael [1 ]
Bautista Ramos, Cesar [1 ]
机构
[1] Benemerita Univ Autonoma Puebla, Fac Ciencias Computac, Puebla, Mexico
来源
SISTEMAS & TELEMATICA | 2018年 / 16卷 / 45期
关键词
Pulse; oximeter; WebSoket; node.[!text type='js']js[!/text; microcontroller; ESP8266;
D O I
10.18046/syt.v16i45.2746
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this work, we describe the design and construction of a pulse oximeter for remote patient monitoring. The proposed device uses the ESP8266 microcontroller as the core component to establish the wireless connection and send information to a node.js server. Then, a web service shows the saturation of oxygen and the heart rate through a WebSocket connection. This paper describes the hardware and software designs, justifying the decision to select each component of the proposed device. Finally, some experimental results are shown to illustrate the performance of the developed prototype.
引用
收藏
页码:9 / 18
页数:10
相关论文
共 50 条
  • [31] Rapid prototyping of pulse oximeter
    Jalan, P.
    Bracio, B. R.
    Rider, P. J.
    Toniolo, H.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 5993 - +
  • [32] Pulse oximeter ear probe
    Avidan, A
    ANAESTHESIA, 2003, 58 (07) : 726 - 726
  • [33] Methaemoglobinaemia, pulse oximeter and burns
    Goutorbe, Philippe
    Meaudre, Eric
    Ascencio, Yves
    Bordes, Julien
    Dantzer, Eric
    BURNS, 2008, 34 (05) : 736 - 736
  • [34] Black henna and pulse oximeter
    Kashimutt, S.
    ANAESTHESIA, 2014, 69 : 84 - 84
  • [35] Artifactual pulse oximeter trace
    Oglesby, K. J.
    Marjot, R.
    ANAESTHESIA, 2013, 68 (05) : 531 - 531
  • [36] A DANGEROUS FAILURE OF A PULSE OXIMETER
    BROOME, IJ
    ANAESTHESIA, 1990, 45 (02) : 166 - 166
  • [37] THE PULSE OXIMETER - VERSATILITY AND FALLIBILITY
    WALLACE, CT
    CHARIKER, FG
    ALPERT, CC
    COOKE, JE
    BAKER, JD
    SOUTHERN MEDICAL JOURNAL, 1986, 79 (09) : 4 - 4
  • [38] EVALUATION OF A NEW PULSE OXIMETER
    CAMERON, PD
    GLENSKI, JA
    MILDE, JH
    GRONERT, GA
    ANAESTHESIA AND INTENSIVE CARE, 1985, 13 (02) : 202 - 202
  • [39] FINGER PULSE OXIMETER RESPONSE
    VIDEIRA, RLR
    NETO, PPR
    AMARAL, RVG
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (02): : 189 - 190
  • [40] SKIN INJURY WITH A PULSE OXIMETER
    BETHUNE, DW
    BALIGA, N
    BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (06) : 665 - 665