LIQUID-CHROMATOGRAPHY ELECTROCHEMICAL DETECTION OF HYDROXYLAMINES BY OXIDATION AT A COBALT PHTHALOCYANINE CHEMICALLY-MODIFIED ELECTRODE

被引:53
|
作者
QI, XH [1 ]
BALDWIN, RP [1 ]
机构
[1] UNIV LOUISVILLE,DEPT CHEM,LOUISVILLE,KY 40292
关键词
HYDROXYLAMINES; ELECTROCATALYSIS; LIQUID CHROMATOGRAPHY; MODIFIED ELECTRODES;
D O I
10.1002/elan.1140060502
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemically modified electrodes (CMEs) containing a polymeric coating of cobalt phthalocyanine (CoPC) were shown to catalyze the electrooxidation of hydroxylamine (NH2OH) and its N-mono-, N,N-di-, and O-substituted derivatives. All of these compounds were oxidized at unmodified glassy carbon electrodes only at potentials higher than + 1 V (vs. Ag/AgCl) but gave substantial anodic currents between +).25 and +0.55 V at the CoPC-containing surface. On the basis of exhaustive electrolysis experiments, the number of electrons transferred for the oxidations was found to vary between 1.2 and 1.6 depending on the particular hydroxylamine compound and the specific conditions of the electrolysis; and the products included oximes, azoxy compounds, and dimeric species. These observations were consistent with an electrocatalytic mechanism involving oxidation of the hydroxylamine by electrogenerated Co(III)PC and subsequent reaction of the initially formed oxidation products by several pathways. When the CoPC CME was used as the sensor in amperometric detection following liquid chromatography the detection limits obtained at +0.55 V ranged from 0.4 pmol for hydroxylamine itself up to 40 pmol for N,O-dimethylhydroxylamine. By maintaining the applied potential at +0.20 V, the detection could be made selective for hydroxylamine and N-mono-substituted hydroxylamine compounds only.
引用
收藏
页码:353 / 360
页数:8
相关论文
共 50 条
  • [21] Liquid chromatography/electrochemical detection of phenols at a poly[Ni-(Protoporphyrin IX)] chemically modified electrode
    DallOrto, VC
    Danilowicz, C
    Sobral, S
    LoBalbo, A
    Rezzano, I
    ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) : 195 - 199
  • [22] LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    KISSINGER, PT
    ACTA PHARMACEUTICA SUECICA, 1982, 19 (01): : 64 - 65
  • [23] ELECTROCATALYTIC DETECTION OF COBALT IN LIQUID-CHROMATOGRAPHY
    TAKATA, Y
    MIZUNIWA, F
    MAEKOYA, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 196 - 196
  • [24] LIQUID-CHROMATOGRAPHY WITH SERIES DUAL-ELECTRODE ELECTROCHEMICAL DETECTION FOR RIBOFLAVIN
    HOU, WY
    WANG, E
    ANALYST, 1990, 115 (02) : 139 - 141
  • [25] ELECTROCHEMICAL DETECTION OF IONS IN LIQUID-CHROMATOGRAPHY
    OSTROVIDOV, EA
    KULESHOVA, LA
    MITINA, SI
    VINOGRADOVA, RG
    VORONTSOV, AM
    KANEV, AS
    RYSEV, OA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1980, 35 (09): : 1089 - 1092
  • [26] PULSED ELECTROCHEMICAL DETECTION IN LIQUID-CHROMATOGRAPHY
    JOHNSON, DC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 71 - ANYL
  • [27] INDIRECT ELECTROCHEMICAL DETECTION IN LIQUID-CHROMATOGRAPHY
    YE, JN
    BALDWIN, RP
    RAVICHANDRAN, K
    ANALYTICAL CHEMISTRY, 1986, 58 (11) : 2337 - 2340
  • [28] MICELLAR LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    KHALEDI, MG
    DORSEY, JG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 187 (APR): : 84 - ANYL
  • [29] LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION OF PEPTIDES
    SAUTER, A
    PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1988, 10 (01) : 32 - 33
  • [30] VOLTAMMETRIC AND AMPEROMETRIC STUDIES OF THIOCHOLINE AT A SCREEN-PRINTED CARBON ELECTRODE CHEMICALLY-MODIFIED WITH COBALT PHTHALOCYANINE - STUDIES TOWARDS A PESTICIDE SENSOR
    HART, JP
    HARTLEY, IC
    ANALYST, 1994, 119 (02) : 259 - 263