GEOTEXTILE STRAIN IN A FULL-SCALE REINFORCED TEST EMBANKMENT

被引:20
|
作者
ROWE, RK
GNANENDRAN, CT
机构
[1] Geotechnical Research Centre, Faculty of Engineering Science, The University of Western Ontario, London
关键词
D O I
10.1016/0266-1144(94)00015-6
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A geotextile reinforced test embankment was constructed on a soft organic clayey silt deposit at Sackville, New Brunswick, Canada in September/October 1989. A relatively high-strength polyester woven geotextile (ultimate strength of 216 kN m(-1)) was used as reinforcement. The reinforcement was instructed with a number of electrical resistance, electro-mechanical and mechanical gauges. The details of this instrumentation and field performance of the geotextile reinforcement during the construction of this test embankment are described in this paper. The field data indicated that the strain in the geotextile was comparatively small (typically less than about 0.7%) up to an embankment thickness of 3.4 m. The strain increased to a maximum of about 2% when the embankment thickness was increased about 4.1 m, suggesting the initiation of movement (or yielding) of the foundation soil. A large increase of strain was evident for thickness exceeding 5.7 m and the available evidence indicates that the soil approached failure at a fill thickness of about 5.7 m. The strain increased to over 8.5% when the embankment was first constructed to 8.2 thickness and then failed as the soil continued to deform at constant fill thickness and the geotextile strain increased until failure (inferred tearing) of the geotextile occurred. After the embankment failed at a thickness of 8.2 m, the addition of more fill did not result in any increase in the net embankment height of 6.6 m, reached just prior to failure of the geotextile. However, although the embankment exhibited signs of distress and large deformations, there was no classical rotation collapse at 8.2 m fill thickness.
引用
收藏
页码:781 / 806
页数:26
相关论文
共 50 条
  • [41] THE DEVELOPMENT OF A FULL-SCALE ROOM FIRE TEST
    WICKSTROM, U
    SUNDSTROM, B
    HOLMSTEDT, G
    [J]. FIRE SAFETY JOURNAL, 1983, 5 (3-4) : 191 - 197
  • [42] FULL-SCALE TEST OF ASPIDE SYSTEM SLATED
    不详
    [J]. AVIATION WEEK & SPACE TECHNOLOGY, 1983, 118 (16): : 182 - 182
  • [43] Full-Scale Field Test of Wake Steering
    Fleming, Paul
    Annoni, Jennifer
    Scholbrock, Andrew
    Quon, Eliot
    Dana, Scott
    Schreck, Scott
    Raach, Steffen
    Haizmann, Florian
    Schlipf, David
    [J]. WAKE CONFERENCE 2017, 2017, 854
  • [44] PREDICTION OF FULL-SCALE FRACTURE WITH A LABORATORY TEST
    MCCLURE, GM
    [J]. MATERIALS PROTECTION, 1966, 5 (01): : 44 - &
  • [45] Lessons from a full-scale fire test
    Izzuddin, BA
    Moore, DB
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2002, 152 (04) : 319 - 329
  • [46] FULL-SCALE TEST OF A COMPOSITE TRUSS.
    Bjorhovde, Reidar
    [J]. Structural Engineering Report, 1981, (97):
  • [47] Full-scale cold bending demonstration test
    Gergess, Antoine N.
    Sen, Rajan
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (10) : 1295 - 1304
  • [48] Geometric and strain behavior of full scale geotextile tubes for dewatering sludge
    Paranhos, S. T. de Souza
    Aparicio-Ardila, M. A.
    da Silva, J. L.
    [J]. GEOSYNTHETICS INTERNATIONAL, 2023, 31 (02) : 187 - 202
  • [49] Seismic performance of full-scale reinforced concrete columns
    Bae, Sungjin
    Bayrak, Oguzhan
    [J]. ACI STRUCTURAL JOURNAL, 2008, 105 (02) : 123 - 133
  • [50] Results of a Full-Scale Fault-Offset Test on a Glass Fiber Reinforced Polymer Pipe
    Williams, Hendrik
    Fam, Amir
    Moore, Ian