IS THERE A RELATIONSHIP BETWEEN REGIONAL MICROSPHERE DISTRIBUTION AND HEPATIC ARTERIAL BLOOD-FLOW

被引:6
|
作者
ANDERSON, JH
ANGERSON, WJ
WILLMOTT, N
KERR, DJ
MCARDLE, CS
COOKE, TG
机构
[1] STRATHCLYDE UNIV, DEPT PHARM, GLASGOW G1, SCOTLAND
[2] UNIV GLASGOW, CANC RES CTR, DEPT ONCOL, GLASGOW G61 1BD, SCOTLAND
关键词
D O I
10.1038/bjc.1992.258
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The relationship between hepatic arterial albumin microsphere distribution and hepatic arterial blood flow and the effects of regional angiotensin 11 were studied in a rat liver metastases model. Hooded-Lister rats were inoculated subcapsularly with 2 x 10(6) HSN sarcoma cells. At 20 days, hepatic arterial blood flow was measured using the reference microsphere technique. Animals then randomly received 50-mu-l hepatic arterial saline or albumin microspheres (40-mu-m, 20 mg ml-1). Hepatic arterial blood flow measurements were then repeated at 5 min. After 5 min, animals were killed and tissues were weighed and counted in a gamma well counter. There were no significant differences between the hepatic blood flow measurements recorded before and after the control hepatic arterial saline infusion. However, regional albumin microspheres produced a significant reduction in tumour and normal liver blood flow and an 80% reduction in mean T/N blood flow ratio. Regional albumin microspheres were delivered to tumour in greater proportions (mean T/N ratio 3.89, SE 0.49) than would be expected from baseline hepatic arterial blood flow (mean T/N ratio 1.28, SE 0.22. P = 0.006). There was no correlation between T/N for baseline blood flow and albumin microsphere distribution.
引用
收藏
页码:287 / 289
页数:3
相关论文
共 50 条
  • [11] MECHANISM OF CONTROL OF HEPATIC ARTERIAL BLOOD-FLOW
    LAUTT, WW
    EZZAT, W
    LEGARE, DJ
    [J]. GASTROENTEROLOGY, 1984, 86 (05) : 1155 - 1155
  • [12] RELATIONSHIP BETWEEN REGIONAL BLOOD-FLOW AND MYOCARDIAL-INFARCTION - EFFECTS OF APPARENT MICROSPHERE LOSS AND-OR TISSUE SWELLING
    COBB, FR
    MURDOCK, RH
    MCHALE, PA
    GREENFIELD, JC
    [J]. CIRCULATION, 1979, 60 (04) : 117 - 117
  • [13] THE MICROSPHERE METHOD FACILITATES STATISTICAL ASSESSMENT OF REGIONAL BLOOD-FLOW
    NOSE, Y
    NAKAMURA, T
    NAKAMURA, M
    [J]. BASIC RESEARCH IN CARDIOLOGY, 1985, 80 (04) : 417 - 429
  • [14] AN ADDITIONAL SOURCE OF ERROR IN MICROSPHERE MEASUREMENT OF REGIONAL BLOOD-FLOW
    MOORE, CD
    GEWERTZ, BL
    WHEELER, HT
    FRY, WJ
    [J]. MICROVASCULAR RESEARCH, 1981, 21 (03) : 377 - 383
  • [15] DETERMINATION OF REGIONAL BLOOD-FLOW BY A RADIOACTIVELY LABELED MICROSPHERE TECHNIQUE
    FOY, JM
    PURVIS, JR
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1981, 74 (01) : P314 - P314
  • [16] EFFECTS OF MICROSPHERE SIZE ON CORONARY AND REGIONAL BLOOD-FLOW MEASUREMENTS
    FAN, FC
    CHEN, RYZ
    SCHUESSLER, GB
    USAMI, S
    CHIEN, S
    [J]. FEDERATION PROCEEDINGS, 1982, 41 (04) : 1351 - 1351
  • [17] RELATIONSHIP BETWEEN BRAIN BLOOD-FLOW AND CAROTID ARTERIAL FLOW IN THE SHEEP FETUS
    VANBEL, F
    ROMAN, C
    KLAUTZ, RJM
    TEITEL, DF
    RUDOLPH, AM
    [J]. PEDIATRIC RESEARCH, 1994, 35 (03) : 329 - 333
  • [18] MEASUREMENT OF REGIONAL HEPATIC BLOOD-FLOW BY SCINTIPHOTOSPLENOPORTOGRAPHY
    KASHIWAGI, T
    KIMURA, K
    KAMADA, T
    ABE, H
    [J]. ACTA HEPATO-GASTROENTEROLOGICA, 1978, 25 (04): : 260 - 266
  • [19] The study of the relationship between arterial blood pressure and blood flow distribution
    Lee, TC
    Tang, ST
    Young, ST
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 3076 - 3078
  • [20] RELATIONSHIP BETWEEN INTRARENAL DISTRIBUTION OF BLOOD-FLOW AND RENIN SECRETION
    ABE, Y
    OKAHARA, T
    KISHIMOTO, T
    YAMAMOTO, K
    UEDA, J
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1973, 225 (02): : 319 - 323