Experimental and Safety Evaluation of Cold-Formed Steel Standing-Seam Metal Roof Panels

被引:5
|
作者
Koshy, Mini [1 ]
Jayachandran, S. Arul [1 ]
机构
[1] Indian Inst Technol Madras, Dept Civil Engn, Madras 600036, Tamil Nadu, India
关键词
D O I
10.1061/(ASCE)SC.1943-5576.0000378
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Failure of metal roof is the most commonly observed damage in cyclones. Significant numbers of metal roof coverings, corners, and eaves are damaged. International codes of practice specify the procedure for the calculation of structural capacity of purlins supporting standing-seam metal roof (SSMR) systems, but they do not specify the procedure to design the panel-purlin connection system, integrated by a clip called a halter. The panel profiles and fastening techniques adopted worldwide are so diverse that the strength of panel-purlin connection and the lateral restraint on purlin by diaphragm action cannot be generalized. However, the type of standing-seam system presented in this paper, viz., the clip lock system, is prevalent in many countries with uniformity in halter dimensions and seam heights. The details of an experimental investigation on prototype cold-formed steel (CFS) standing-seam clip lock system tested under wind uplift in a vacuum chamber are presented here. A vacuum chamber was fabricated specially for this purpose, as per standards. The behavior and failure modes of rigid purlin-panel system were studied. Experimental data on the uplift behavior of SSMR were gathered. This data were converted to design parameters through statistical evaluation. Three limit states of panel-purlin interaction failure were studied and a procedure for the integral design of SSMR halter-rigid purlin systems was developed, guided by the experimental results. On the design effect side, four wind-pressure cases, along with cyclonic wind pressure, were considered. The applicability of the experimental results to practical designs was quantified by a reliability-based analysis. Based on the values of reliability indices, the zones of failure were identified, and a rational design of variable halter length was proposed. The halter length could be adjusted as per the target reliability, leading to the concept of SSMR roof system with a uniform safety. (C) 2018 American Society of Civil Engineers.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Analysis of temperature field and effect of cold-formed stainless steel roof panels
    Wang, Dayang
    Xin, Zhiyong
    Wang, Mingming
    Ou, Tong
    Mao, Jihua
    Zhu, Yong
    Tan, Jian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 198
  • [2] Analysis of temperature field and effect of cold-formed stainless steel roof panels
    Wang, Dayang
    Xin, Zhiyong
    Wang, Mingming
    Ou, Tong
    Mao, Jihua
    Zhu, Yong
    Tan, Jian
    Journal of Constructional Steel Research, 2022, 198
  • [3] Experimental investigation on composite panels of cold-formed steel and timber
    Kyvelou, Pinelopi
    Reynolds, Thomas P. S.
    Beckett, Christopher T. S.
    Huang, Yuner
    ENGINEERING STRUCTURES, 2021, 247
  • [4] Experimental investigation on composite panels of cold-formed steel and timber
    Kyvelou, Pinelopi
    Reynolds, Thomas P.S.
    Beckett, Christopher T.S.
    Huang, Yuner
    Engineering Structures, 2021, 247
  • [5] COLD-FORMED STEEL PANELS WITH RIVETED CONNECTIONS
    YENER, M
    WHITE, RN
    JOURNAL OF STRUCTURAL ENGINEERING, 1984, 110 (05) : 1035 - 1050
  • [6] Design of cold-formed steel curved panels
    Casariego, P.
    Casafont, M.
    Ferrer, M.
    Marimon, F.
    STRUCTURES AND ARCHITECTURE, 2010, : 577 - 584
  • [7] Analysis of Natural Vibration Characteristics of Metal Roof Panel of Large-Span Standing-Seam Metal Roof System
    Xie, Zhen
    Zhang, Yongshan
    BUILDINGS, 2023, 13 (11)
  • [8] Design criteria for seam and sheeting-to-framing connections of cold-formed steel shear panels
    Fülöp, LA
    Dubina, D
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2006, 132 (04): : 582 - 590
  • [9] Bending capacity of cold-formed Z-purlins supporting a standing seam roof system with torsional bracing
    Ramseyer, Chris
    Shadravan, Shideh
    JOURNAL OF STRUCTURAL INTEGRITY AND MAINTENANCE, 2016, 1 (04) : 177 - 188
  • [10] Sheathing Bracing Requirements for Cold-formed Steel Wall Panels: Experimental Investigation
    Selvaraj, Sivaganesh
    Madhavan, Mahendrakumar
    STRUCTURES, 2019, 19 : 258 - 276