TRANSIENT AC VOLTAGE RELATED PHENOMENA FOR HVDC SCHEMES CONNECTED TO WEAK AC SYSTEMS

被引:27
|
作者
PILOTTO, LAS
SZECHTMAN, M
HAMMAD, AE
ANDERSSON, G
LISS, G
机构
[1] ABB POWER SYST AB,LUDVIKA,SWEDEN
[2] ABB ASEA BROWN BOVERI,CH-5401 BADEN,SWITZERLAND
关键词
VOLTAGE STABILITY; HVDC CONVERTER CONTROLS; DIGITAL SIMULATION;
D O I
10.1109/61.141857
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A didactic explanation of voltage stability associated phenomena at HVDC terminals is presented. Conditions leading to ac voltage collapse problems are identified. A mechanism that excites control-induced voltage oscillations is shown. The voltage stability factor is used for obtaining the maximum power limits of ac/dc systems operating with different control strategies. Correlation to Pd x Id curves is given. Solutions for eliminating the risks of voltage collapse and for avoiding control-induced oscillations are discussed. The results are supported by detailed digital simulations of a weak ac/dc system using EMTP.
引用
收藏
页码:1396 / 1404
页数:9
相关论文
共 50 条
  • [41] Dynamic Reactive Compensation Requirements at the Rectifier End of an LCC HVDC Link Connected to a Weak AC System
    ElMehdi, Abosalah
    Momen, Ahmed
    Johnson, Brian K.
    2014 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2014,
  • [42] PERFORMANCE EVALUATION OF AN HVDC LINK WITH A CAPACITOR COMMUTATED INVERTER CONNECTED TO A VERY WEAK RECEIVING AC NETWORK
    Khatir, Mohamed
    Zidi, Sid-Ahmed
    Fellah, Mohammed-Karim
    Hadjeri, Samir
    Amiri, Rabie
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2009, 60 (04): : 209 - 214
  • [43] COMPARISON OF SUITABLE CONTROL-SYSTEMS FOR HVDC STATIONS CONNECTED TO WEAK AC-SYSTEMS .2. OPERATIONAL BEHAVIOR OF HDVC TRANSMISSION
    RUMPF, E
    RANADE, S
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (02): : 555 - &
  • [44] Improved Decoupling Control Strategy of MMC-HVDC System Connected to the Weak AC Power Grid
    Bingkun Li
    Hongguang Li
    Gang Wang
    Journal of Electrical Engineering & Technology, 2022, 17 : 819 - 833
  • [45] Improved Decoupling Control Strategy of MMC-HVDC System Connected to the Weak AC Power Grid
    Li, Bingkun
    Li, Hongguang
    Wang, Gang
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (02) : 819 - 833
  • [46] System Analysis and Simulation Experimental Research of VSC-MMC HVDC Connected to AC Weak System
    Yang W.
    Zhang S.
    Yu H.
    Liu B.
    Dianwang Jishu/Power System Technology, 2021, 45 (06): : 2457 - 2464
  • [47] A Frequency-Based Synchronization Approach for the VSC-HVDC Station Connected to a Weak AC Grid
    Guo, Chunyi
    Liu, Wei
    Zhao, Chengyong
    Iravani, Reza
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (03) : 1460 - 1470
  • [48] STABILIZERS ENHANCING THE FREQUENCY REGULATION ACTION OF HVDC LINKS SUPPLYING WEAK AC SYSTEMS
    MARIS, TI
    LYGDIS, AD
    VOVOS, NA
    GIANNAKOPOULOS, GB
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER ENGINEERING, 1993, 3 (03): : 201 - 212
  • [49] Supplementary Frequency-Voltage Damping Control for LCC-MMC Hybrid HVDC System Connected to Extremely Weak Receiving AC Grid
    Wang Y.
    Guo C.
    Zheng A.
    Yin Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (07): : 1509 - 1520
  • [50] ANALYTICAL STUDY OF HVDC LINK WITH STATIC VAR COMPENSATORS IN WEAK AC-SYSTEMS
    OOI, BT
    HELLAL, A
    ELECTRIC MACHINES AND POWER SYSTEMS, 1988, 14 (01): : 1 - 16