THE SINGLE-BREATH NITROGEN TEST, MORTALITY, AND CANCER

被引:7
|
作者
VESTBO, J
RASMUSSEN, FV
机构
[1] BISPEBJERG HOSP,DEPT MED P,DK-2400 COPENHAGEN,DENMARK
[2] BISPEBJERG HOSP,CHEST CLIN,DK-2400 COPENHAGEN,DENMARK
[3] RIGSHOSP,OCCUPAT MED CLIN,DK-2100 COPENHAGEN,DENMARK
[4] HILLEROD HOSP,DEPT MED B,HILLEROD,DENMARK
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1990年 / 142卷 / 05期
关键词
D O I
10.1164/ajrccm/142.5.1022
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The relationship between indices of the single-breath nitrogen test and mortality, overall cancer incidence, and respiratory cancer incidence was examined in a cohort of 876 men, 46 to 69 yr of age, examined in 1974 and followed until June 1985. Closing volume, closing capacity, and slope of phase III were not related to mortality or cancer. In contrast, FEV1 was related to mortality, with an estimated relative mortality risk of 1.37 (95% confidence interval, 1.11 to 1.70) per liter under the expected FEV1, given height, age, and smoking, but FEV1 was not related to cancer. Inability to perform acceptable single-breath nitrogen test tracings was related to mortality with a relative mortality risk of 2.03 (1.45 to 2.85), but not to cancer. We conclude that indices of the single-breath nitrogen test have no predictive value concerning overall mortality and cancer incidence.
引用
收藏
页码:1022 / 1025
页数:4
相关论文
共 50 条
  • [21] NEW SINGLE-BREATH TEST OF RESPIRATORY-FUNCTION
    NICHOL, GM
    GUY, HJB
    NEW ZEALAND MEDICAL JOURNAL, 1979, 89 (633) : 280 - 280
  • [22] SIGNIFICANCE OF THE TERMINAL RISE IN THE SINGLE-BREATH OXYGEN TEST
    CURTIS, JK
    RASMUSSEN, HK
    AMERICAN REVIEW OF TUBERCULOSIS AND PULMONARY DISEASES, 1957, 75 (05): : 745 - 755
  • [23] FAST SINGLE-BREATH ROOM-AIR (SBRA) NITROGEN WASHOUT TEST - VARIABILITY IN A SINGLE-SUBJECT
    SAYRE, RM
    FLORES, XF
    LEE, SJ
    CRUZ, JC
    FASEB JOURNAL, 1994, 8 (05): : A691 - A691
  • [24] A functional mathematical model to simulate the single-breath nitrogen washout
    Barbini, Paolo
    Brighenti, Chiara
    Gnudi, Gianni
    Open Biomedical Engineering Journal, 2013, 7 : 81 - 92
  • [25] COMPUTERIZED SINGLE-BREATH NITROGEN WASHOUT IN CHILDREN - VARIABILITY AND REPRODUCIBILITY
    TECULESCU, DB
    PHAM, QT
    HANNHART, B
    MELET, JJ
    MARCHAND, M
    HENQUEL, JC
    CLINICAL PHYSIOLOGY, 1987, 7 (03): : 247 - 259
  • [26] COMPUTER-ANALYSIS OF SINGLE-BREATH NITROGEN WASHOUT CURVE
    CRAVEN, N
    SIDWALL, G
    WEST, P
    MCCARTHY, DS
    CHERNIACK, RM
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1976, 113 (04): : 445 - 449
  • [27] DETERMINATION OF LUNG-VOLUME BY SINGLE-BREATH AND MULTIPLE-BREATH NITROGEN WASHOUT
    ABBOUD, RT
    MORTON, JM
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1977, 115 (03): : 545 - 546
  • [28] The single breath nitrogen test and mortality - A 38 years follow up
    Olofson, Jan
    Bake, Bjorn
    Bergman, Bengt
    Svardsudd, Kurt
    RESPIRATORY MEDICINE, 2016, 112 : 75 - 80
  • [29] CLINICAL USEFULNESS OF SINGLE-BREATH PULMONARY DIFFUSING CAPACITY TEST
    BURROWS, B
    NIDEN, AH
    KASIK, JE
    BARCLAY, WR
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1961, 84 (06): : 789 - &
  • [30] EFFECT OF POSTURE ON SINGLE-BREATH OXYGEN TEST IN NORMAL SUBJECTS
    CORTESE, DA
    RODARTE, JR
    REHDER, K
    HYATT, RE
    JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (04) : 474 - 479