Assessment of left ventricular regional wall motion abnormalities using regional time-volume curves obtained by real time three-dimensional echocardiography

被引:4
|
作者
Youssef, Ghada [1 ]
Saad, Zakarya [1 ]
Ammar, Waleed [1 ]
Sharaf, Yasser [1 ]
机构
[1] Cairo Univ, Dept Cardiovasc Med, Cairo, Egypt
来源
EGYPTIAN HEART JOURNAL | 2018年 / 70卷 / 03期
关键词
RT3D echocardiography; Wall motion; Abnormalities; Left ventricular regional function;
D O I
10.1016/j.ehj.2018.02.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Three-dimensional echocardiography provides a volumetric measurement of global and regional left ventricular (LV) function. It avoids the subjectivity of 2D echocardiography in the assessment of regional wall motion abnormalities (RWMA). Purpose: Evaluate the feasibility and practicality of 3D echocardiography in the evaluation of ischemic patients with abnormal regional LV contractility. Methods: The study included 40 patients with ischemic heart disease and RWMA as well as 30 control subjects. They underwent routine clinical examination and conventional 2D echocardiographic assessment. Segments were categorized as; normal, hypokinetic; akinetic or dyskinetic. Three-dimensional echocardiographic images were acquired and later on analyzed offline. Global LV function was semiautomatically calculated by the machine using volumetric measurements. Regional LV function was calculated manually for the 17 LV segments by detecting the end-diastolic (EDD) and end-systolic (ESD) points on the specific segment volume curve and the regional ejection fraction (EF) was calculated by the following formula {(EDDx-ESDx)/EDDx}, where x represents the specific segment. Regional EF was compared between patients and control subjects. Results: The mean age was 55.0 +/- 8.0 and 32.6 +/- 8.5 years (P < 0.001) in patients and control groups, respectively. No statistically significant difference in EF between 2D and 3D images (47.3 +/- 10.5 vs 48. 0 +/- 8.0, p = 0.6). There was a good correlation between the 2D-RWMA and 3D-regional EF, and this correlation was consistent in the whole 17 segments. Conclusion: Three-dimensional echocardiography is an easy, non-invasive and objective tool to detect regional wall motion abnormalities in ischemic patients. It shows comparable results with conventional 2D images with the advantage of quantitative assessment of regional myocardial function. (C) 2018 Egyptian Society of Cardiology. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
  • [41] Real-time three-dimensional echocardiography for regional evaluation of aortic stiffness
    Nemes, Attila
    Geleijnse, Marcel L.
    Soliman, Osama I. I.
    Anwar, Ashraf M.
    Vletter, Wim B.
    ten Cate, Folkert J.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (02): : 161 - 162
  • [42] Real-time three-dimensional echocardiography for measurement of left ventricular volumes
    Schmidt, MA
    Ohazama, CJ
    Agyeman, KO
    Freidlin, RZ
    Jones, M
    Laurienzo, JM
    Brenneman, CL
    Arai, AE
    von Ramm, OT
    Panza, JA
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (12): : 1434 - 1439
  • [43] Real time three-dimensional echocardiography: Measurement of left ventricular mass in dogs
    Fleishman, CE
    Ota, T
    Ohazama, CJ
    Stetten, G
    Lewis, CW
    Li, J
    vonRamm, OT
    Kisslo, J
    CIRCULATION, 1996, 94 (08) : 4019 - 4019
  • [44] REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS
    Hong-wen Fei* Xin-fang Wang
    Chinese Medical Sciences Journal, 2004, (03) : 230 - 232
  • [45] Left ventricular ejection fraction by real-time three-dimensional echocardiography
    van Dalen, B. M.
    NETHERLANDS HEART JOURNAL, 2014, 22 (09) : 380 - 382
  • [46] Real Time Three-Dimensional Echocardiographic Assessment of Left Ventricular Regional Systolic Function and Dyssynchrony in Patients with Dilated Cardiomyopathy
    Mu, Yuming
    Chen, Lu
    Tang, Qi
    Ayoufu, Guligena
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (04): : 415 - 420
  • [47] Value of left ventricular regional ejection fraction determined by real-time three-dimensional echocardiography in diagnosis of aneurysm: compared with left ventriculography
    Li Xiu-chang
    Yan Cheng-jun
    Yao Gui-hua
    Zhang Mei
    Li Ji-Fu
    Zhang Yun
    CHINESE MEDICAL JOURNAL, 2009, 122 (24) : 2981 - 2984
  • [48] Value of left ventricular regional ejection fraction determined by real-time three-dimensional echocardiography in diagnosis of aneurysm: compared with left ventriculography
    LI Xiu-chang
    Key Laboratory of Cardiovascular Remodeling and Function Research
    中华医学杂志(英文版), 2009, (24) : 2981 - 2984
  • [49] Accuracy of left ventricular mass measurements using real-time three-dimensional echocardiography
    Schmidt, MA
    Laurienzo, JM
    Brenneman, CL
    Freidlin, RZ
    Ohazamas, CJ
    Jones, M
    Panza, JA
    CIRCULATION, 1998, 98 (17) : 153 - 153
  • [50] Early Left Atrial Mechanics and Volume Abnormalities in Subjects with Prehypertension: A Real Time Three-Dimensional Echocardiography Study
    Akturk, Erdal
    Ermis, Necip
    Yagmur, Julide
    Acikgoz, Nusret
    Kurtoglu, Ertugrul
    Cansel, Mehmet
    Eyupkoca, Ferhat
    Pekdemir, Hasan
    Ozdemir, Ramazan
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (10): : 1211 - 1217