AMBULATORY 24-HOUR BLOOD-PRESSURE MONITORING - SIGNIFICANCE OF BLOOD-PRESSURE VARIABILITY FOR THE PROGRESSION OF CARDIAC-HYPERTROPHY

被引:0
|
作者
MACHNIG, T [1 ]
ENGELS, G [1 ]
HENNEKE, KH [1 ]
GELLERT, J [1 ]
BACHMANN, K [1 ]
机构
[1] BAYER AG, KFD, W-5600 WUPPERTAL 1, GERMANY
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 1993年 / 82卷 / 03期
关键词
AMBULATORY BLOOD PRESSURE MONITORING; BLOOD PRESSURE VARIABILITY; LEFT VENTRICULAR HYPERTROPHY; FOURIER ANALYSIS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It is known that ambulatory blood-pressure monitoring gives a better prediction of target organ damage and prognosis than clinical blood pressure. Many studies have found a closer correlation for ambulatory blood pressure with left ventricular hypertrophy than clinical blood pressure. One question that is discussed controversely is whether the variability of blood pressure is also a determinant of target organ damage independent of the average level. In 52 patients with elevated casual blood pressure a 24-h ambulatory blood-pressure measurement (Space Labs 90202) was performed and left ventricular hypertrophy was evaluated by M-mode echocardiography. The following parameters of blood pressure variability were calculated from the profiles: the standard deviation of the mean value, the variation coefficient and the parameter of variability as proposed by Schachinger et al. (17). Furthermore a Fourier analysis of the blood pressure data was performed to quantify blood pressure variability. We found no statistically significant correlation between blood pressure variability and left ventricular mass. However, systolic and diastolic blood pressure level showed a significant correlation with left ventricular hypertrophy (r = 0.45 and r = 0.49, p < 0.05). Thus, blood pressure variability as calculated from the ambulatory, non-invasive blood pressure monitoring is a poor predictor for secondary damage of the heart.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [21] NONINVASIVE 24-HOUR AMBULATORY ARTERIAL BLOOD-PRESSURE MONITORING IN CIRRHOSIS
    MOLLER, S
    WIINBERG, N
    HENRIKSEN, JH
    HEPATOLOGY, 1995, 22 (01) : 88 - 95
  • [22] 24 HOUR INTERMITTENT, AMBULATORY BLOOD-PRESSURE MONITORING
    EGGER, M
    BIANCHETTI, MG
    GNADINGER, M
    KOBELT, R
    OETLIKER, O
    ARCHIVES OF DISEASE IN CHILDHOOD, 1987, 62 (11) : 1130 - 1135
  • [23] EFFICACY OF ONCE-DAILY AMLODIPINE IN THE CONTROL OF 24-HOUR BLOOD-PRESSURE USING AMBULATORY BLOOD-PRESSURE MONITORING
    HURAIB, S
    ASKAR, A
    ABUAISHA, H
    ALWAKEEL, J
    MITWALLI, A
    ALMAJED, S
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1995, 56 (11): : 1125 - 1131
  • [24] PROGNOSTIC VALUE OF 24-HOUR BLOOD-PRESSURE VARIABILITY
    FRATTOLA, A
    PARATI, G
    CUSPIDI, C
    ALBINI, F
    MANCIA, G
    JOURNAL OF HYPERTENSION, 1993, 11 (10) : 1133 - 1137
  • [26] CLINICAL-SIGNIFICANCE AND COST-EFFECTIVENESS OF 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING
    IMAI, Y
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1995, 176 (01): : 1 - 15
  • [27] THE BERGEN BLOOD-PRESSURE STUDY - 24-HOUR AMBULATORY BLOOD-PRESSURE IS INCREASED IN OFFSPRING OF HYPERTENSIVE PARENTS
    MO, R
    LUNDJOHANSEN, P
    OMVIK, P
    JOURNAL OF HYPERTENSION, 1993, 11 : S70 - S71
  • [28] AMBULATORY 24-HOUR BLOOD-PRESSURE VERSUS SELF-MEASURED BLOOD-PRESSURE IN PHARMACOLOGICAL TRIALS
    MENGDEN, T
    WEISSER, B
    VETTER, W
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1994, 24 : S20 - S25
  • [29] DETERMINATION OF BLOOD-PRESSURE LOAD IN CHILDREN BY THE USE OF 24-HOUR AMBULATORY BLOOD-PRESSURE MONITOR (ABPM)
    PORTMAN, RJ
    YETMAN, RJ
    WEST, MS
    PEDIATRIC RESEARCH, 1989, 25 (04) : A104 - A104
  • [30] 24-HOUR BLOOD-PRESSURE MONITORING AND EFFECTS OF INDAPAMIDE
    OCON, J
    MORA, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (17): : H58 - H61