ASSESSMENT OF THE FETOMATERNAL CIRCULATION IN THREATENED-ABORTION BY TRANSVAGINAL COLOR DOPPLER

被引:20
|
作者
KURJAK, A
ZUDENIGO, D
PREDANIC, M
KUPESIC, S
FUNDUK, B
机构
[1] Department of Obstetrics and Gynecology, Medical School, University of Zagreb
关键词
FETOMATERNAL CIRCULATION; THREATENED ABORTION; TRANSVAGINAL COLOR DOPPLER;
D O I
10.1159/000263959
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Transvaginal color Doppler was used to investigate blood flow in the fetomaternal circulation of 60 women with threatened abortion and 90 women with normal intrauterine pregnancy. The obtained Doppler sonograms were analyzed and the resistance index (RI) was calculated in the maternal circulation, while in the fetal circulation the pulsatility index (PI) was used. There was no significant difference in the RI values of the maternal circulation between women with normal pregnancies and pregnancies complicated by bleeding, but with normal pregnancy outcome (p > 0.05). No differences in RI values of the uterine, arcuate and radial arteries were found between pregnancies with threatened abortion and normal pregnancy outcome and women with abnormal outcome (p > 0.05). In 9 of 21 women with visible retrochorionic hematoma, the RI of the spiral arteries was higher on the hematoma side in comparison to the opposite side (p < 0.01). This could be a consequence of the mechanical compression caused by the hematoma. In 3 of 4 cases of missed abortion, the RI of the spiral arteries was lower in comparison to the control group. Such findings could be caused by the vasodilatating products of inflammation which probably exist in such areas. There was no significant difference in terms of the PI of fetal blood vessels between normal pregnancy and threatened abortions with normal outcome, as well as between threatened abortions with normal outcome and subsequent abortions of live fetuses (p > 0.05).
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [31] ULTRASOUND VISUALIZATION OF INTRAUTERINE HEMATOMATA IN THREATENED-ABORTION
    MANTONI, M
    PEDERSEN, JF
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (642): : 546 - 546
  • [32] INTRAUTERINE HEMATOMA AN ULTRASONIC STUDY OF THREATENED-ABORTION
    MANTONI, M
    PEDERSEN, JF
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1981, 88 (01): : 47 - 51
  • [33] INTRAUTERINE HEMATOMA - A PROGNOSTIC ENIGMA IN THREATENED-ABORTION
    RAYMOND, FR
    DONO, FV
    THOMAS, RJ
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1985, 85 (01): : 27 - 32
  • [34] ULTRASOUND OF THE EMPTY GESTATION SAC IN THREATENED-ABORTION
    SCOTT, RF
    FEATHERSTONE, T
    HUSSEY, JK
    CLINICAL RADIOLOGY, 1987, 38 (02) : 127 - 130
  • [35] PREDICTIVE VALUE OF HORMONE MEASUREMENTS IN THREATENED-ABORTION
    HERTZ, JB
    CONTRACEPTIVE DELIVERY SYSTEMS, 1982, 3 (3-4) : 402 - 402
  • [36] BIRTH-DEFECTS IN RELATION TO THREATENED-ABORTION
    ZHANG, J
    OLSHAN, A
    CAI, WW
    EPIDEMIOLOGY, 1994, 5 (03) : 341 - 344
  • [37] TRANSVAGINAL COLOR DOPPLER ASSESSMENT OF UTEROPLACENTAL CIRCULATION IN NORMAL AND ABNORMAL EARLY-PREGNANCY
    KURJAK, A
    KUPESICUREK, S
    PREDANIC, M
    SALIHAGIC, A
    EARLY HUMAN DEVELOPMENT, 1992, 29 (1-3) : 385 - 389
  • [38] Transvaginal color Doppler assessment of the uteroplacental circulation in normal and abnormal pregnancies in the first trimester
    Dilmen, G
    Turhan, NO
    Seckin, NC
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1996, 52 (03) : 285 - 286
  • [39] PROGNOSTIC VALUE OF BIOCHEMICAL TESTS IN THE ASSESSMENT OF FETAL-OUTCOME IN THREATENED-ABORTION
    SALEM, HT
    GHANEIMAH, SA
    SHAABAN, MM
    CHARD, T
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (04): : 382 - 385
  • [40] HORMONE LEVELS AND FETAL DEVELOPMENT IN CASES OF THREATENED-ABORTION
    TOJO, S
    ASHITAKA, Y
    KATAYAMA, K
    CONTRACEPTIVE DELIVERY SYSTEMS, 1982, 3 (3-4) : 361 - 361