A new method for single-phase high resistance grounding fault protection in low resistance grounded distribution networks

被引:0
|
作者
Wang, Gang [1 ,2 ]
Wang, Liyi [1 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan, Peoples R China
[2] Shandong Univ, Sch Elect Engn, Jinan 250061, Peoples R China
关键词
cluster analysis; cosine distance; high resistance grounding fault; improved K-means algorithm; low resistance grounded distribution network;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The neutral point of the distribution network is grounded with low resistance, which can quickly remove single-phase grounding fault and effectively suppress overvoltage. However, the existing zero-sequence overcurrent protection has a high setting value. In the case of large fault resistance and weak fault current, the existing protection methods may refuse to operate. Based on the waveform characteristics of the zero-sequence current of each outgoing line in the distribution network, this article proposes a new method for single-phase high resistance grounding fault protection in low resistance grounded distribution network, which combines cosine distance and improved K-means algorithm. First, the cosine distance between zero-sequence current of every two outgoing lines is obtained, and the cosine distance matrix used to describe the fault characteristics is constructed. Then the improved K-means algorithm is used to cluster the row vectors of the cosine distance matrix to obtain the convergent cluster center and cluster label, so that the fault line can be determined. This protection method does not need to set the threshold value manually, and has strong ability to handle large fault resistance. It can effectively deal with noise interference and intermittent arc grounding fault, and still has good adaptability in scenarios such as change of fault initial phase angle, change of fault location, access of distributed generations and occurrence of two outgoing lines in phase to grounding fault. Finally, a model is built, and the effectiveness of the proposed method is proved by the simulation of grounding fault.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Novel flexible and adaptive arc suppression method for single-phase grounding fault in distribution network
    You, Jianzhang
    Guo, Moufa
    Cai, Wenqiang
    Gao, Wei
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (04): : 146 - 153
  • [42] Single-phase Grounding Fault Location Method for Distribution Network Based on Convolutional Neural Network
    Liang, Jiefeng
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 672 - 677
  • [43] Identifying Faulty Feeder for Single-Phase High Impedance Fault in Resonant Grounding Distribution System
    Tang, Tao
    Huang, Chun
    Li, Zhenxing
    Yuan, Xiuguang
    ENERGIES, 2019, 12 (04)
  • [44] Grounding fault protection based on fault resistance measurement for ineffectively earthed distribution systems
    School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410076, China
    不详
    Gaodianya Jishu, 2007, 1 (26-30): : 26 - 30
  • [45] Characteristic Analysis of Single-phase Grounding Fault in Resonant Grounded Systems based-on HHT
    Xiao, Yingwei
    Wu, Hongbin
    Zhang, Lin
    Xiao, Benxian
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 1563 - 1568
  • [46] Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network
    Jianrui Li
    Yongli Li
    Yonghuan Wang
    Jinzhao Song
    GlobalEnergyInterconnection, 2021, 4 (06) : 564 - 575
  • [47] Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network
    Li, Jianrui
    Li, Yongli
    Wang, Yonghuan
    Song, Jinzhao
    GLOBAL ENERGY INTERCONNECTION-CHINA, 2021, 4 (06): : 564 - 575
  • [48] High Resistance Ground Fault Protection of Low Resistance Grounding System Based on Zero Sequence Current Projection Coefficient
    Yang F.
    Liu X.
    Shen Y.
    Xue Y.
    Zhou Z.
    Xu B.
    Dianwang Jishu/Power System Technology, 2020, 44 (03): : 1128 - 1133
  • [49] Single-phase grounding fault detection method for a distribution network based on phase voltage difference polarity value
    Liu F.
    Zeng X.
    Xie L.
    Yu K.
    Tang X.
    Wang Y.
    Deng Q.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (15): : 155 - 165
  • [50] Grounding Fault Protection Algorithm of Small Resistance Earthing Active Distribution Network Based on Phase Difference
    Li, Jun
    He, Min
    Huang, Shoudao
    Liu, Jun
    Liu, Zhiyong
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (23): : 7418 - 7429