THE USE OF AVERAGED ELECTRODE VOLTAGES TO ASSESS THE FUNCTION OF NUCLEUS INTERNAL COCHLEAR IMPLANT DEVICES IN CHILDREN

被引:15
|
作者
MAHONEY, MJ
PROCTOR, LAR
机构
[1] Carle Clinic Association Urbana, IL
来源
EAR AND HEARING | 1994年 / 15卷 / 02期
关键词
D O I
10.1097/00003446-199404000-00007
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Averaged electrode voltages (AEVs) provide an objective measure of the output of the Nucleus multichannel cochlear implant device. AEVs are the peak-to-peak voltages of each electrode in the internal array and are recorded from electrodes placed on the scalp. This article summarizes average voltage data for 25 children with complete insertions of the electrode array. Data are compared with previously published adult data and are evaluated based on the location of the recordings (clinic versus operating room). AEV data can be applied clinically to identify implant problems. AEV recordings for this purpose are particularly important with children who may not be able to provide accurate reports of implant function. Case studies are presented to illustrate the application of the AEV procedure to examine implant malfunction in six children.
引用
收藏
页码:177 / 183
页数:7
相关论文
共 50 条
  • [41] Stream segregation on a single electrode as a function of pulse rate in cochlear implant listeners
    Duran, Sara I.
    Collins, Leslie M.
    Throckmorton, Chandra S.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 132 (06): : 3849 - 3855
  • [42] Speech development in children and insertion depth of the cochlear implant electrode array.
    Adamczyk, M
    Bachor, E
    Bagus, H
    Fischer, M
    LARYNGO-RHINO-OTOLOGIE, 2001, 80 (03): : 123 - 126
  • [43] Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implant
    Henkin, Y
    Kaplan-Neeman, R
    Muchnik, C
    Kronenberg, J
    Hildesheimer, M
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2003, 67 (08) : 873 - 880
  • [44] Piloting the recording of electrode voltages (REVS) using surface electrodes as a test to identify cochlear implant electrode migration, extra-cochlear electrodes and basal electrodes causing discomfort
    Grasmeder, Mary
    Verschuur, Carl
    Ferris, Robyn
    Basodan, Sundus
    Newman, Tracey
    Sanderson, Alan
    COCHLEAR IMPLANTS INTERNATIONAL, 2021, 22 (03) : 157 - 169
  • [45] SPEECH-PERCEPTION WITH THE NUCLEUS COCHLEAR IMPLANT IN CHILDREN TRAINED WITH THE AUDITORY VERBAL APPROACH
    TYLER, RS
    AMERICAN JOURNAL OF OTOLOGY, 1990, 11 (02): : 99 - 107
  • [46] Frequency Mapping of a Precurved Electrode Array in the Internal Auditory Canal for a Pediatric Cochlear Implant Recipient
    Anderson, Melissa R.
    Dedmon, Matthew M.
    Thompson, Nicholas J.
    Park, Lisa R.
    Brown, Kevin D.
    Dillon, Margaret T.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (07) : E276 - E279
  • [47] PERFORMANCE OF ADULT INERAID AND NUCLEUS COCHLEAR IMPLANT PATIENTS AFTER 3.5 YEARS OF USE
    TYLER, RS
    LOWDER, MW
    PARKINSON, AJ
    WOODWORTH, GG
    GANTZ, BJ
    AUDIOLOGY, 1995, 34 (03): : 135 - 144
  • [48] Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implant
    Fu, QJ
    Shannon, RV
    Galvin, JJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (04): : 1664 - 1674
  • [49] Does depth of electrode insertion influence inner ear function in cochlear implant patients?
    Klenzner, T
    Neumann, M
    Marangos, N
    Laszig, R
    4TH EUROPEAN CONGRESS OF OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, VOLS 1 AND 2, 2000, : 43 - 47
  • [50] Factors Affecting Daily Cochlear Implant Use in Children: Datalogging Evidence
    Easwar, Vijayalakshmi
    Sanfilippo, Joseph
    Papsin, Blake
    Gordon, Karen
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2016, 27 (10) : 824 - 838