BONE-DENSITY AFTER RIGID PLATE FIXATION OF TIBIAL FRACTURES - A DUAL-ENERGY X-RAY ABSORPTIOMETRY STUDY

被引:25
|
作者
JANES, GC [1 ]
COLLOPY, DM [1 ]
PRICE, R [1 ]
SIKORSKI, JM [1 ]
机构
[1] SIR CHARLES GAIRDNER HOSP,DEPT ENDOCRINOL,BONE STRUCT UNIT,NEDLANDS,WA 6009,AUSTRALIA
来源
关键词
D O I
10.1302/0301-620X.75B6.8245081
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation, Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia, An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences out weigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture.
引用
收藏
页码:914 / 917
页数:4
相关论文
共 50 条
  • [31] BROAD-BAND ULTRASOUND ATTENTUATION COMPARED WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY IN SCREENING FOR POSTMENOPAUSAL LOW BONE-DENSITY
    YOUNG, H
    HOWEY, S
    PURDIE, DW
    OSTEOPOROSIS INTERNATIONAL, 1993, 3 (03) : 160 - 164
  • [32] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE FOREARM
    ROOS, JC
    TENKROODE, K
    LIPS, P
    TEULE, GJJ
    VANLINGEN, A
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P110 - P111
  • [33] ASSOCIATION OF DIGITAL X-RAY RADIOGRAMMETRY WITH FRAX AND DUAL-ENERGY X-RAY ABSORPTIOMETRY: THE STUDY OF OSTEOPOROTIC FRACTURES
    Kalvesten, J.
    Lui, L. -Y.
    Brismar, T. B.
    Cummings, S. R.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : S113 - S113
  • [34] Osteoporosis after gastrectomy: bone mineral density of lumbar spine assessed by dual-energy X-ray absorptiometry
    Adachi, Y
    Shiota, E
    Matsumata, T
    Iso, Y
    Yoh, R
    Kitano, S
    CALCIFIED TISSUE INTERNATIONAL, 2000, 66 (02) : 119 - 122
  • [35] ACRONYM FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY
    WILSON, CR
    COLLIER, BD
    CARRERA, GF
    JACOBSON, DR
    RADIOLOGY, 1990, 176 (03) : 875 - 875
  • [36] Dual-energy x-ray absorptiometry in obesity
    Bazzocchi, Alberto
    Diano, Danila
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2014, 186 (01) : 48 - 48
  • [37] An Update on Dual-Energy X-Ray Absorptiometry
    Blake, Glen M.
    Fogelman, Ignac
    SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (01) : 62 - 73
  • [38] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE NEWBORN
    SALLE, BL
    LAPILLONNE, A
    BRAILLON, P
    ARCHIVES FRANCAISES DE PEDIATRIE, 1993, 50 (07): : 545 - 546
  • [39] LIMITATIONS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TOTHILL, P
    NORD, RH
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 398 - 399
  • [40] REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    CHILIBECK, P
    CALDER, A
    SALE, DG
    WEBBER, C
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (04): : 297 - 302