Diagnosis of corrosion of the steel reinforcement of concrete structures in zones of influence of stray currents

被引:0
|
作者
Kucera, Bohumil [1 ]
Jankowski, Jezmar [2 ]
Sokolski, Wojciech [2 ]
机构
[1] JEKU Sro, Prague, Czech Republic
[2] SPZP CORRPOL Sp Zoo, Gdansk, Poland
来源
OCHRONA PRZED KOROZJA | 2016年 / 59卷 / 12期
关键词
corrosion; concrete reinforcement; stray currents; corrosion diagnostics; electrical resistance technique;
D O I
10.15199/41.2016.12.4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The acquired experience has been presented in selection of methods and equipment for monitoring of corrosion during the designing process of protection means against stray current interaction on steel reinforcement of some reinforced concrete structures. Long-term observations have been described of reinforcement corrosion progress with CMS recording systems, consecutively supplemented by concrete resistivity probes, aggressive agent penetration depth probes into reinforcement, and primarily with corrosion rate probes. During the past 15 years over 150 electrical resistance probes have been installed in various objects in the Czech Republic. The application method of this measurement technique has been described. Interesting applications of the technique have been presented on chosen bridge structures.
引用
下载
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [21] Influence of steel reinforcement corrosion on the stiffness of simply supported concrete beams
    O'Flaherty, F. J.
    Mangat, P. S.
    Lambert, P.
    Lambert, E. H.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE-CYCLE OPTIMIZATION, 2010, : 3442 - 3447
  • [22] Corrosion of reinforcement in concrete structures in India
    Reddi, SA
    CORROSION AND ITS CONTROLS, VOLS I AND II, 1998, : 58 - 80
  • [23] Corrosion protection of reinforcement for concrete structures
    Wilmot, R. E.
    JOURNAL OF THE SOUTH AFRICAN INSTITUTE OF MINING AND METALLURGY, 2007, 107 (03): : 139 - 146
  • [24] A probabilistic prediction model for the corrosion initiation time of steel reinforcement in concrete structures
    Li, Linyuan
    Damrongwiriyanupap, Nattapong
    Xi, Yunping
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2011, 14 (1-2) : 112 - 120
  • [25] Corrosion of discontinuous reinforcement in concrete subject to railway stray alternating current
    Tang, Kangkang
    CEMENT & CONCRETE COMPOSITES, 2020, 109
  • [26] Maintenance Scenario of Concrete Structures Damaged by Reinforcement Corrosion Based on Corrosion Propagation Mechanism of Steel and Moisture Behavior in Concrete
    Takaya, Satoshi
    Saito, Ryosuke
    Satoh, Shinichi
    Yamamoto, Takashi
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2021, 19 (06) : 614 - 629
  • [27] Spatial identification of exposure zones of concrete structures exposed to a marine environment with respect to reinforcement corrosion
    Bourreau, Lucas
    Gaillet, Laurent
    Bouteiller, Veronique
    Schoefs, Franck
    Thauvin, Benoit
    Schneider, Julien
    Naar, Samuel
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2020, 16 (02) : 346 - 354
  • [28] Stray current induced corrosion of steel fibre reinforced concrete
    Tang, Kangkang
    CEMENT AND CONCRETE RESEARCH, 2017, 100 : 445 - 456
  • [29] Influence of specimen dimensions and reinforcement corrosion on bond performance of steel bars in concrete
    Zhang, Bai
    Zhu, Hong
    Chen, Jun
    Yang, Ou
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (09) : 1759 - 1771
  • [30] Influence of steel-concrete interface quality on reinforcement corrosion induced by chlorides
    Castel, A
    Vidal, T
    François, R
    Arliguie, G
    MAGAZINE OF CONCRETE RESEARCH, 2003, 55 (02) : 151 - 159