FINGERS - 3-DIMENSIONAL MR-IMAGING AND ANGIOGRAPHY WITH A LOCAL GRADIENT COIL

被引:14
|
作者
BLACKBAND, SJ [1 ]
CHAKRABARTI, I [1 ]
GIBBS, P [1 ]
BUCKLEY, DL [1 ]
HORSMAN, A [1 ]
机构
[1] UNIV NEWCASTLE UPON TYNE,DEPT ORTHOPAED,NEWCASTLE TYNE,ENGLAND
关键词
ARTERIES; EXTREMITIES; FINGERS AND TOES; HAND; MR;
D O I
10.1148/radiology.190.3.8115647
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors interfaced a 12-cm-diameter local gradient coil with a solenoid radio-frequency coil (2.2-cm internal diameter, 1.4-cm long) to a recalibrated clinical magnetic resonance imaging system. Three-dimensional gradient-echo imaging and phase-contrast angiography were performed on the fingers of five healthy volunteers (four men and one woman, aged 23-33 years). Data sets (256 x 256 x 28) were acquired with spatial resolution of 100 x 100 x 500 mu m in 6 minutes 51 seconds. The angiograms clearly delineated blood vessels that were less than 1 mm in diameter.
引用
收藏
页码:895 / 899
页数:5
相关论文
共 50 条
  • [21] CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST
    LI, D
    PASCHAL, CB
    HAACKE, EM
    ADLER, LP
    [J]. RADIOLOGY, 1993, 187 (02) : 401 - 406
  • [22] CT, MR-IMAGING AND ANGIOGRAPHY IN PANCREATIC APUDOMAS
    ASPESTRAND, F
    KOLMANNSKOG, F
    JACOBSEN, M
    [J]. ACTA RADIOLOGICA, 1993, 34 (05) : 468 - 473
  • [23] RADIOSURGICAL TREATMENT PLANNING OF BRAIN METASTASES BASED ON A FAST, 3-DIMENSIONAL MR-IMAGING TECHNIQUE
    SCHAD, LR
    BLUML, S
    HAWIGHORST, H
    WENZ, F
    LORENZ, WJ
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (05) : 811 - 819
  • [24] MR-IMAGING AND MR-ANGIOGRAPHY IN THE EVALUATION OF PULSATILE TINNITUS
    DIETZ, RR
    DAVIS, WL
    HARNSBERGER, HR
    JACOBS, JM
    BLATTER, DD
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (05) : 879 - 889
  • [25] OPTIMIZING STRATEGY FOR MR-IMAGING GRADIENT COILS
    ADAMIAK, K
    CZAJA, AJ
    RUTT, BK
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (06) : 4311 - 4313
  • [26] 3-DIMENSIONAL DOSE MAPPING FROM GAMMA KNIFE TREATMENT USING A DOSIMETER GEL AND MR-IMAGING
    OLSSON, LE
    ARNDT, J
    FRANSSON, A
    NORDELL, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 24 (02) : 82 - 86
  • [27] 3-DIMENSIONAL MR-IMAGING AND DISPLAY OF INTRACRANIAL DISEASE - IMPROVEMENTS WITH THE MP-RAGE SEQUENCE AND GADOLINIUM
    BRANTZAWADZKI, MN
    GILLAN, GD
    ATKINSON, DJ
    EDALATPOUR, N
    JENSEN, M
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 656 - 662
  • [28] DIAGNOSTIC ADVANTAGES OF 3-DIMENSIONAL (FOURIER-TRANSFORM) MR-IMAGING IN SPINAL-CORD LESIONS
    VOIGT, K
    THRON, A
    SCHROTH, G
    [J]. NEURORADIOLOGY, 1985, 27 (04) : 366 - 366
  • [29] VARIATIONS IN VENOUS AND SEGMENTAL ANATOMY OF THE LIVER - 2-DIMENSIONAL AND 3-DIMENSIONAL MR-IMAGING IN HEALTHY-VOLUNTEERS
    VANLEEUWEN, MS
    FERNANDEZ, MA
    VANES, HW
    STOKKING, R
    DILLON, EV
    FELDBERG, MAM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (06) : 1337 - 1345
  • [30] SELECTIVE 3-DIMENSIONAL MR IMAGING OF THE SPINE
    GALLIMORE, GW
    HARMS, SE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) : 124 - 128