A FAST READOUT SYSTEM FOR 2D GAS-FILLED DETECTORS BASED ON THE DELAY-LINE METHOD

被引:7
|
作者
BERRY, A
GABRIEL, A
KOCSIS, M
RIEKEL, C
机构
[1] EUROPEAN SYNCHROTRON RES FACIL,BP 220,F-38043 GRENOBLE,FRANCE
[2] ILL GRENOBLE,EUROPEAN MOLEC BIOL LAB,F-38042 GRENOBLE,FRANCE
关键词
D O I
10.1016/0168-9002(94)90757-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new generation of high brilliance synchrotron radiation sources such as the ESRF requires detectors with improved counting rate capability and resolution. Gas filled detectors are of particular interest for small-angle scattering applications due to their low inherent background. A counting rate increase of delay-line based 2D detectors is possible through the reduction of the delay line and a modularisation of the detector. To this end a new readout system has been designed based on VME/VXI modules. The heart of the system is a Time-to-Digital Converter (TDC) with 50 ps resolution (at 200 MHz master clock frequency). Counting rates in excess of 1.8 MHz have been demonstrated with a 100 x 100 mm2 detector and 20 ns delay line. A further improvement of the TDC should allow counting rates up to 5 MHz.
引用
收藏
页码:334 / 337
页数:4
相关论文
共 50 条
  • [1] DUAL TIME TO DIGITAL CONVERTER FOR DELAY-LINE READOUT OF POSITION-SENSITIVE GAS-FILLED DETECTORS
    BERRY, A
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05): : 1222 - 1228
  • [2] A beginners' guide to gas-filled proportional detectors with delay line readout
    Petrascu, AM
    Koch, MHJ
    Gabriel, A
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE-PHYSICS, 1998, B37 (04): : 463 - 483
  • [3] Digitized signal acquisition of gas-filled, multiwire, neutron detector with delay-line readout
    Orban, J.
    Rosta, L.
    Nagy, A.
    [J]. INTERNATIONAL WORKSHOP ON NEUTRON OPTICS AND DETECTORS (NOP&D 2013), 2014, 528
  • [4] Fast and compact data acquisition for gas-filled detectors with delay line
    Toledo, J
    Beltrán, D
    Bordas, J
    Ramos-Lerate, I
    Martínez, JC
    Fernández, F
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1488 - 1491
  • [5] A fast and compact histogramming solution for gas-filled detectors with delay line
    Toledo, J
    Beltrán, D
    Bordas, J
    Ramos-Lerate, I
    Martínez, JC
    Fernández, F
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1685 - 1688
  • [6] A self contained Linux based data acquisition system for 2D detectors with delay line readout
    Beltran, D.
    Toledo, J.
    Klora, A. C.
    Ramos-Lerate, I.
    Martinez, J. C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 570 (03): : 511 - 517
  • [7] A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout
    Hanu, A. R.
    Prestwich, W. V.
    Byun, S. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 33 - 39
  • [8] De-Li-DAQ-2D - a New Data Acquisition System for Position-Sensitive Neutron Detectors with Delay-Line Readout
    Levchanovskiy, F. V.
    Murashkevich, S. M.
    [J]. PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2016, 13 (05) : 591 - 594
  • [9] A fast position encoding system for a delay line based gas filled area detector
    Epstein, A
    Boulin, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) : 1931 - 1933
  • [10] A PCI DAQ board for MWPC detectors with high-rate 2D delay line position readout
    Levchanovski, FV
    Gebauer, B
    Litvinenko, EI
    Nikiforov, AS
    Prikhodko, VI
    Schulz, C
    Wilpert, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 413 - 416