摘要
The capacitance-voltage (C-V) technique is one of the most powerful and direct methods to investigate interface traps in metal-insulator-semiconductor (MIS or MOS) related devices. As the C-V technique is of such fundamental importance in detecting and monitoring process related defects the systematic measurement concerns, misinterpretations and limitations associated with the equipment used to implement this technique must be fully understood and characterized. This study reports the results of a detailed comparison of both the (raw) measured C-V curve and the (analyzed) interface trap density versus energy data obtained using commercially available quasistatic meters, specifically the Hewlett-Packard (HP) model 4140B quasistatic/dc picoammeter and the Keithley model 595 quasistatic meter. © 1990 The Mineral, Metal & Materials Society, Inc.
引用
下载
收藏
页码:637 / 650
页数:14
相关论文
共 50 条
  • [31] QUASI-STATIC ADHESIVE FRACTURE
    MAI, YW
    JOURNAL OF ADHESION, 1975, 7 (02): : 141 - 153
  • [32] Quasi-static brittle fracture
    Dept. of Materials Science and Engineering, Univ. of Pennsylvania, Philadelphia, PA 19104, United States
    不详
    不详
    Mater Res Soc Symp Proc, (313-318):
  • [33] Quasi-static large deviations
    De Masi, Anna
    Olla, Stefano
    ANNALES DE L INSTITUT HENRI POINCARE-PROBABILITES ET STATISTIQUES, 2020, 56 (01): : 524 - 542
  • [34] Quasi-Static Hydrodynamic Limits
    Anna De Masi
    Stefano Olla
    Journal of Statistical Physics, 2015, 161 : 1037 - 1058
  • [35] QUASI-STATIC GROWTH OF CRACKS
    CHUDNOVSKII, AI
    DUNAEVSKII, VA
    KHANDOGIN, VA
    ARCHIVES OF MECHANICS, 1978, 30 (02): : 165 - 174
  • [36] Static and quasi-static calibration of a bioMEMS device
    Slifka, AJ
    Panchawagh, H
    Mahajan, RL
    Finch, D
    Rorrer, RAL
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 429 - 434
  • [37] The quasi-static method revisited
    Dulla, Sandra
    Mund, Ernest H.
    Ravetto, Piero
    PROGRESS IN NUCLEAR ENERGY, 2008, 50 (08) : 908 - 920
  • [38] Quasi-Static Hydrodynamic Limits
    De Masi, Anna
    Olla, Stefano
    JOURNAL OF STATISTICAL PHYSICS, 2015, 161 (05) : 1037 - 1058
  • [39] QUASI-STATIC CRACK PROPAGATION
    GURNEY, C
    HUNT, J
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1967, 299 (1459): : 508 - &
  • [40] A comparison of non-quasi-static and quasi-static harmonic balance implementations for coupled device and circuit simulation