PARTICLE-INDUCED X-RAY-EMISSION (PIXE) FOR DETECTION OF LEAD IN MOUSE BLASTOCYSTS

被引:0
|
作者
NILSSON, BO
LINDH, U
SUNDE, T
WIDE, M
机构
[1] DEPT RADIAT SCI,DIV PHYS BIOL,S-75121 UPPSALA,SWEDEN
[2] DEPT ZOOL,S-75122 UPPSALA,SWEDEN
关键词
MOUSE; EXPERIMENTALLY DELAYED IMPLANTATION; BLASTOCYST; LEAD; PIXE; PARTICLE INDUCED X-RAY MICROANALYSES;
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Mice were injected intravenously with lead chloride, 75-mu-g/g body weight. The mice were in an experimental delay of implantation, which offered the functionally steady conditions required for developing the testing procedures. One day after the administration of lead, blastocysts were flushed from the uterine cavity, placed on thin foils of Kapton, and air-dried. The dried blastocysts were analyzed in a nuclear microprobe with a particle intensity of 10 nanoampere (nA) for 300 s using a spatial resolution of 3-mu-m. The average lead concentration of blastocysts at implantation was 3.90-mu-g/g dry weight. We judge this technique to be useful for evaluating the transport of heavy metals from mother to preembryos, not only under the present experimental conditions but also in normal pregnancies and in other species.
引用
收藏
页码:53 / 55
页数:3
相关论文
共 50 条
  • [11] Analytical applications of particle-induced X-ray emission (PIXE)
    Popescu, I. V.
    Ene, A.
    Stihi, C.
    Bancuta, A.
    Dima, G.
    Badica, T.
    Ghisa, V.
    SIX INTERNATIONAL CONFERENCE OF THE BALKAN PHYSICAL UNION, 2007, 899 : 538 - 538
  • [12] RECENT PROGRESS IN PARTICLE INDUCED X-RAY-EMISSION ANALYSIS (PIXE)
    JOHANSSON, SAE
    CHEMIA ANALITYCZNA, 1990, 35 (1-3): : 167 - 188
  • [14] LEAD DETERMINATIONS IN HUMAN BONE BY PARTICLE-INDUCED X-RAY-EMISSION (PIXE) AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY (GFAAS)
    DEIBEL, MA
    SAVAGE, JM
    ROBERTSON, JD
    EHMANN, WD
    MARKESBERY, WR
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 195 (01): : 83 - 89
  • [15] PARTICLE-INDUCED X-RAY-EMISSION (PIXE) ANALYSIS OF BIOLOGICAL-MATERIALS - PRECISION, ACCURACY AND APPLICATION TO CANCER TISSUES
    MAENHAUT, W
    DEREU, L
    VANRINSVELT, HA
    CAFMEYER, J
    VANESPEN, P
    NUCLEAR INSTRUMENTS & METHODS, 1980, 168 (1-3): : 557 - 562
  • [16] ELEMENTAL ANALYSIS OF GOLD COINS BY PARTICLE INDUCED X-RAY-EMISSION (PIXE)
    FERREIRA, GP
    GIL, FB
    ARCHAEOMETRY, 1981, 23 (AUG) : 189 - 197
  • [17] LINKING PARTICLE BACKSCATTERING AND PARTICLE-INDUCED X-RAY-EMISSION - THE CASE FOR AN INTEGRATED SYSTEM
    LISCHOLZ, A
    SCHOLZ, W
    STEVENSON, KA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 56-7 : 772 - 775
  • [18] ELEMENTAL ANALYSIS OF OBSIDIAN ARTIFACTS BY PROTON PARTICLE-INDUCED X-RAY-EMISSION
    NIELSON, KK
    HILL, MW
    MANGELSON, NF
    NELSON, FW
    ANALYTICAL CHEMISTRY, 1976, 48 (13) : 1947 - 1950
  • [19] APPLICABILITY OF MICROWAVE ACID DIGESTION TO SAMPLE PREPARATION OF BIOLOGICAL-MATERIALS FOR ANALYSIS BY PARTICLE-INDUCED X-RAY-EMISSION (PIXE)
    PINHEIRO, T
    DUFLOU, H
    MAENHAUT, W
    BIOLOGICAL TRACE ELEMENT RESEARCH, 1990, 26-7 : 589 - 597
  • [20] PARTICLE-INDUCED X-RAY EMISSION (PIXE) ANALYSIS OF OBSIDIAN FROM TEOTIHUACAN
    Gazzola, J.
    Del Rio, M. Sanchez
    Solis, C.
    Calligaro, T.
    ARCHAEOMETRY, 2010, 52 : 343 - 354