A SIMPLE METHOD FOR COUNTING SMALL NUMBERS OF CELLS BY FLOW-CYTOMETRY

被引:0
|
作者
BLASS, S
LENNARTZ, K
机构
来源
ZEITSCHRIFT FUR NATURFORSCHUNG C-A JOURNAL OF BIOSCIENCES | 1991年 / 46卷 / 11-12期
关键词
ENUMERATION OF VIABLE CELLS; FACS; FLUORESCENT MICROSPHERES; RAT BRAIN CELLS;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We describe a flow cytometric method for the quantitation of small numbers of cells that facilitates proliferation studies in microcultures. A constant number of fluorescent latex microspheres/sample is added to single cell suspensions prepared from the cultures. By flow cytometric analysis, cells are easily distinguishable from the microspheres and can be quantitated on the basis of their light scattering and fluorescence properties in contour plots. As the number of microspheres/sample is known, the relative proportions of cells and microspheres, respectively, can be converted into absolute cell numbers. This quick method is useful for any type of studies where cell numbers < 1 x 10(5) in a small volume are to be determined.
引用
收藏
页码:1130 / 1133
页数:4
相关论文
共 50 条
  • [31] ANALYSIS OF THE NUMBER OF CHROMOSOMES IN CELLS BY FLOW-CYTOMETRY
    STEPANOV, SI
    VERSHILOVA, EV
    MALINOVSKY, OV
    FILATOV, MV
    TSITOLOGIYA, 1986, 28 (05): : 583 - 586
  • [32] RETICULOCYTE QUANTIFICATION BY FLOW-CYTOMETRY, IMAGE-ANALYSIS, AND MANUAL COUNTING
    SCHIMENTI, KJ
    LACERNA, K
    WAMBLE, A
    MASTON, L
    IAFFALDANO, C
    STRAIGHT, M
    RABINOVITCH, A
    LAZARUS, HM
    JACOBBERGER, JW
    CYTOMETRY, 1992, 13 (08): : 853 - 862
  • [33] ENUMERATION OF ANTIGEN SITES ON CELLS BY FLOW-CYTOMETRY
    DAWSON, CD
    SCHEPPLER, JA
    NICHOLSON, JKA
    HOLMAN, RC
    PATHOBIOLOGY, 1991, 59 (02) : 57 - 61
  • [34] FLOW-CYTOMETRY OF ISOLATED CELLS FROM THE BRAIN
    MEYER, RA
    ZARUBA, ME
    MCKHANN, GM
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1980, 2 (01): : 66 - 74
  • [35] FLOW-CYTOMETRY TO OVERCOME INTERFERENCES IN IMPEDANCE-BASED LEUKOCYTE COUNTING
    LOUAGIE, H
    MOREAU, E
    PHILIPPE, J
    LEROUXROELS, G
    CLINICAL CHEMISTRY, 1995, 41 (03) : 479 - 480
  • [36] FEATURES OF APOPTOTIC CELLS MEASURED BY FLOW-CYTOMETRY
    DARZYNKIEWICZ, Z
    BRUNO, S
    DELBINO, G
    GORCZYCA, W
    HOTZ, MA
    LASSOTA, P
    TRAGANOS, F
    CYTOMETRY, 1992, 13 (08): : 795 - 808
  • [37] Detachment Procedure of Bacteria from Atmospheric Particles for Flow-cytometry Counting
    Araya, Carolina M.
    Cazorla, Alberto
    Reche, Isabel
    BIO-PROTOCOL, 2019, 9 (12):
  • [38] A SIMPLE DIAGNOSTIC-TEST FOR FANCONI ANEMIA BY FLOW-CYTOMETRY
    MIGLIERINA, R
    LECONIAT, M
    BERGER, R
    ANALYTICAL CELLULAR PATHOLOGY, 1991, 3 (02): : 111 - 118
  • [39] FLOW-CYTOMETRY OF SPERM
    GLEDHILL, BL
    HUMAN REPRODUCTION /: CURRENT STATUS / FUTURE PROSPECT, 1988, 768 : 363 - 369
  • [40] CONTROL OF PROGESTERONE PRODUCTION IN SMALL AND LARGE BOVINE LUTEAL CELLS SEPARATED BY FLOW-CYTOMETRY
    ALILA, HW
    DOWD, JP
    CORRADINO, RA
    HARRIS, WV
    HANSEL, W
    JOURNAL OF REPRODUCTION AND FERTILITY, 1988, 82 (02): : 645 - 655