PULSED DOPPLER TRANSESOPHAGEAL ECHOCARDIOGRAPHIC DETERMINATION OF CARDIAC-OUTPUT IN HUMAN-BEINGS - COMPARISON WITH THERMODILUTION TECHNIQUE

被引:40
|
作者
STODDARD, MF [1 ]
PRINCE, CR [1 ]
AMMASH, N [1 ]
GOAD, JL [1 ]
VOGEL, RL [1 ]
机构
[1] UNIV LOUISVILLE,DEPT STAT,LOUISVILLE,KY 40202
关键词
D O I
10.1016/0002-8703(93)90712-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of cardiac output is a clinically valuable and widely used index of cardiac function. Although transesophageal echocardiography has been used to assess left ventricular function, little data exist on the accuracy of this technique in the measurement of cardiac output. Therefore cardiac output derived by pulsed Doppler transesophageal echocardiography and thermodilution methods were compared in adult patients being mechanically ventilated. The left ventricular outflow tract diameter was determined from a transgastric long-axis view of the left ventricle by using the transverse plane and longitudinal plane of the transesophageal scope. The cross-sectional area of the left ventricular outflow tract was calculated from the diameter assuming a circular shape. Pulsed Doppler recordings were obtained at the left ventricular outflow tract. Doppler time-velocity integrals were measured from the leading edge of the velocity curve. Cardiac output derived by tranesophageal echocardiography was calculated as time-velocity integral multiplied by left ventricular outflow tract area and heart rate. Cardiac output derived by transesophageal echocardiography from the transverse plane (n = 26) and longitudinal plane (n = 22) were correlated with simultaneous thermodilution measurements. Thermodilution-derived cardiac output demonstrated excellent correlation with cardiac output measured by using transesophageal echocardiography from the transverse plane (r = 0.97, SEE = 0.84 L/min; p < 0.0001) and longitudinal plane (r = 0.95, SEE = 0.97 L/min; p < 0.0001). Transesophageal echocardiography is a promising technique in the measurement of cardiac output and expands the clinical use of this modality in the assessment of cardiac function. © 1993.
引用
收藏
页码:956 / 962
页数:7
相关论文
共 50 条
  • [21] PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN
    BERMAN, W
    ELDRIDGE, M
    YABEK, S
    DILLON, T
    ALVERSON, D
    RUPAS, D
    BOUMA, K
    HENDON, L
    CIRCULATION, 1981, 64 (04) : 167 - 167
  • [22] Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients
    Axler, O
    Tousignant, C
    Thompson, CR
    DallavaSantucci, J
    Phang, PT
    Russell, JA
    Walley, KR
    JOURNAL OF CRITICAL CARE, 1996, 11 (03) : 109 - 116
  • [23] COMPARISON OF CARDIAC-OUTPUT MEASURED BY INTRAPULMONARY ARTERY DOPPLER, THERMODILUTION, AND ELECTROMAGNETOMETRY
    HEERDT, PM
    POND, CG
    BLESSIOS, GA
    ROSENBLOOM, M
    ANNALS OF THORACIC SURGERY, 1992, 54 (05): : 959 - 966
  • [24] Transgastric, pulsed Doppler echocardiographic determination of cardiac output
    DescorpsDeclere, A
    Smail, N
    Vigue, B
    Duranteau, J
    Mimoz, O
    Edouard, A
    Samii, K
    INTENSIVE CARE MEDICINE, 1996, 22 (01) : 34 - 38
  • [25] MEASUREMENT OF CARDIAC-OUTPUT WITH THE QUANTASCOPE, A NOVEL DOPPLER DEVICE - COMPARISON WITH THERMODILUTION
    CROSS, SJ
    LEE, HS
    JENNINGS, K
    RAWLES, J
    EUROPEAN HEART JOURNAL, 1993, 14 (06) : 809 - 811
  • [26] 2-BEAM PULSED DOPPLER CARDIAC-OUTPUT MEASUREMENT - REPRODUCIBILITY AND AGREEMENT WITH THERMODILUTION
    WONG, DH
    MAHUTTE, CK
    CRITICAL CARE MEDICINE, 1990, 18 (04) : 433 - 437
  • [27] MEASUREMENT OF CARDIAC-OUTPUT - TRANSTRACHEAL DOPPLER VERSUS THERMODILUTION
    FROESE, N
    FRIESEN, R
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (07): : 931 - 934
  • [28] COMPARISON OF METHODS OF CARDIAC-OUTPUT MEASUREMENTS DETERMINED BY DYE DILUTION, PULSED DOPPLER-ECHOCARDIOGRAPHY AND THERMODILUTION IN HORSES
    MIZUNO, Y
    AIDA, H
    HARA, H
    FUJINAGA, T
    HAGIO, M
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1994, 56 (01): : 1 - 5
  • [29] CARDIAC-OUTPUT DETERMINATION DURING EXERCISE USING DOPPLER ECHO - VALIDATION BY THERMODILUTION
    CHRISTIE, JL
    SHELDAHL, LM
    WANN, LS
    TRISTANI, FE
    SAGAR, KB
    PTACIN, MJ
    WOLF, L
    CLINICAL RESEARCH, 1986, 34 (02): : A289 - A289
  • [30] COMPARISON OF THERMODILUTION, THORACIC ELECTRICAL BIOIMPEDANCE AND DOPPLER ULTRASOUND CARDIAC-OUTPUT MEASUREMENT
    NG, HWK
    WALLEY, TJ
    MOSTAFA, SM
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (01) : 119 - 120