UHV PHOTOELECTRON X-RAY-BEAM POSITION MONITOR

被引:9
|
作者
JOHNSON, ED
OVERSLUIZEN, T
机构
[1] Brookhaven National Laboratory, National Synchrotron Light Source, Upton
基金
美国能源部;
关键词
D O I
10.1016/0168-9002(90)90099-R
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As part of our research program to develop viable beam position monitors for both the X-ray and the VUV beamlines at the NSLS, we have constructed vertical photon beam position monitors which are presently mounted in two front-end tanks in the X-ray ring. These area-type detectors are located before the safety shutters and are, therefore, able to monitor the beam position even during injection. The features of this type of monitor which contribute to its long-term stability, position sensitivity, and immunity to horizontal beam motion have been examined and are discussed. © 1990.
引用
收藏
页码:427 / 430
页数:4
相关论文
共 50 条
  • [21] IMPLEMENTATION OF DIGITAL SUBTRACTION ANGIOGRAPHY WITH A SYNCHROTRON X-RAY-BEAM
    ZEMAN, HD
    HUGHES, EB
    CAMPBELL, LE
    HOFSTADTER, R
    KIRK, RL
    KROLICKI, TJ
    ROLFE, J
    STONE, JP
    WILSON, S
    RUBENSTEIN, E
    THOMPSON, AC
    WALTON, JT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 442 - 446
  • [22] PHASE OSCILLATIONS IN LEAD MONOXIDE UNDER THE X-RAY-BEAM
    SCHOONOVER, JR
    JOURNAL OF SOLID STATE CHEMISTRY, 1992, 100 (02) : 331 - 340
  • [23] An X-ray beam position monitor based on the photoluminescence of helium gas
    Revesz, P
    White, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 540 (2-3): : 470 - 479
  • [24] A NEW BEAM POSITION MONITOR FOR X-RAY SYNCHROTRON RADIATION FACILITIES
    STEFAN, PM
    SIDDONS, DP
    HASTINGS, JB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (03): : 598 - 602
  • [25] THE INSTRUMENTATION OF X-RAY-BEAM LINES WITH PIN DIODE DETECTORS
    JACH, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 76 - 79
  • [26] X-RAY-BEAM METHOD FOR DISPLACEMENT MEASUREMENT IN HOSTILE ENVIRONMENTS
    JORDAN, EH
    PEASE, DM
    CANISTRARO, H
    BREW, D
    HOSTILE ENVIRONMENTS AND HIGH TEMPERATURE MEASUREMENTS, 1989, : 27 - 30
  • [27] COMPACT LABORATORY X-RAY-BEAM LINE WITH FOCUSING MICROOPTICS
    HUDEC, R
    ARNDT, U
    INNEMAN, A
    PINA, L
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 499 - 502
  • [28] X-RAY-BEAM SHEET DEFLECTION FOR LIQUID SURFACE SPECTROMETRY
    WULFF, M
    ALSNIELSEN, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1134 - 1137
  • [29] PATIENT ACTIVATION WITH A 25 MV THERAPEUTIC X-RAY-BEAM
    DUNSCOMBE, PB
    MCLELLAN, J
    HUDA, W
    GILLIES, JM
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (729): : 843 - 846
  • [30] A SUBMICRON SYNCHROTRON X-RAY-BEAM GENERATED BY CAPILLARY OPTICS
    ENGSTROM, P
    LARSSON, S
    RINDBY, A
    BUTTKEWITZ, A
    GARBE, S
    GAUL, G
    KNOCHEL, A
    LECHTENBERG, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (03): : 547 - 552