MASS-SPECTROMETRIC STUDIES ON THE RESPONSE MECHANISM OF SURFACE-IONIZATION DETECTORS FOR GAS-CHROMATOGRAPHY

被引:12
|
作者
FUJII, T [1 ]
JIMBA, H [1 ]
ARIMOTO, H [1 ]
机构
[1] SHIMADZU CO LTD,NAKAGYO,KYOTO 604,JAPAN
关键词
D O I
10.1021/ac00201a004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometric techniques at atmospheric pressure are used to measure the ionic species generated when organic compounds from a gas Chromatograph come into contact with a hot Pt emitter. The intensities and types of ions formed against surface temperature, gas environments around the emitter, and emitter material were investigated. in almost every sample studied, the observed ion species in the mass spectrum are the same as those obtained with SIOMS (surface ionization organic mass spectrometry in vacuum condition) with only the intensity distribution showing differences. The results confirm that positive surface ionization is the mechanism of the production of charge carriers in the surface ionization detector. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 50 条
  • [21] RAPID AND SENSITIVE DETERMINATION OF APRINDINE IN SERUM BY GAS-CHROMATOGRAPHY USING A SURFACE-IONIZATION DETECTOR
    KAWANO, H
    INOTSUME, N
    ARIMOTO, H
    FUJII, T
    NAKANO, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 493 (01): : 71 - 78
  • [22] SENSITIVE DETERMINATION OF MIDAZOLAM IN HUMAN PLASMA BY CAPILLARY GAS-CHROMATOGRAPHY WITH SURFACE-IONIZATION DETECTION
    ARIMOTO, H
    NODA, J
    KOIDE, M
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1992, 15 (03): : 195 - 197
  • [23] SENSITIVE DETERMINATION OF PHENOTHIAZINES IN BODY-FLUIDS BY GAS-CHROMATOGRAPHY WITH SURFACE-IONIZATION DETECTION
    HATTORI, H
    YAMAMOTO, S
    IWATA, M
    TAKASHIMA, E
    YAMADA, T
    SUZUKI, O
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (02): : 247 - 252
  • [25] CAPILLARY GAS-CHROMATOGRAPHY - MASS-SPECTROMETRIC ANALYSIS OF COOKED GROUND-BEEF AROMA
    MACLEOD, G
    AMES, JM
    JOURNAL OF FOOD SCIENCE, 1986, 51 (06) : 1427 - 1434
  • [26] MASS-SPECTROMETRIC CHARACTERIZATION OF DIFFERENT NORANDROSTERONE DERIVATIVES BY LOW-COST MASS-SPECTROMETRIC DETECTORS USING ELECTRON IONIZATION AND CHEMICAL IONIZATION
    DEBOER, D
    DEJONG, EG
    MAES, RAA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (06) : 181 - 185
  • [27] NEW SENSITIVE AND SELECTIVE DETECTOR FOR GAS-CHROMATOGRAPHY - SURFACE-IONIZATION DETECTOR WITH A HOT PLATINUM EMITTER
    FUJII, T
    ARIMOTO, H
    ANALYTICAL CHEMISTRY, 1985, 57 (13) : 2625 - 2628
  • [28] DETERMINATION OF LOCAL-ANESTHETICS IN BODY-FLUIDS BY GAS-CHROMATOGRAPHY WITH SURFACE-IONIZATION DETECTION
    HATTORI, H
    YAMAMOTO, S
    YAMADA, T
    SUZUKI, O
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01): : 278 - 282
  • [29] GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION TANDEM MASS-SPECTROMETRIC QUANTIFICATION OF INDOMETHACIN IN PLASMA AND SYNOVIAL-FLUID
    DAWSON, M
    SMITH, MD
    MCGEE, CM
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (08): : 453 - 458
  • [30] NEW USES OF THERMIONIC IONIZATION DETECTORS IN GAS-CHROMATOGRAPHY
    PATTERSON, PL
    CHROMATOGRAPHIA, 1982, 16 : 107 - 111