MASS-SPECTROMETRIC STUDIES ON THE RESPONSE MECHANISM OF SURFACE-IONIZATION DETECTORS FOR GAS-CHROMATOGRAPHY

被引:12
|
作者
FUJII, T [1 ]
JIMBA, H [1 ]
ARIMOTO, H [1 ]
机构
[1] SHIMADZU CO LTD,NAKAGYO,KYOTO 604,JAPAN
关键词
D O I
10.1021/ac00201a004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometric techniques at atmospheric pressure are used to measure the ionic species generated when organic compounds from a gas Chromatograph come into contact with a hot Pt emitter. The intensities and types of ions formed against surface temperature, gas environments around the emitter, and emitter material were investigated. in almost every sample studied, the observed ion species in the mass spectrum are the same as those obtained with SIOMS (surface ionization organic mass spectrometry in vacuum condition) with only the intensity distribution showing differences. The results confirm that positive surface ionization is the mechanism of the production of charge carriers in the surface ionization detector. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 50 条
  • [1] MASS-SPECTROMETRIC STUDY OF SURFACE-IONIZATION OF TETRAALKYLAMMONIUM SALTS
    RASULEV, UK
    NAZAROV, EG
    TURSUNOV, KS
    ARGUNEEVA, TV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1991, 46 (09): : 1306 - 1312
  • [2] GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRIC ANALYSIS OF DIMINAZENE IN PLASMA
    FOUDA, HG
    BIOMEDICAL MASS SPECTROMETRY, 1978, 5 (01): : 72 - 75
  • [3] GAS-CHROMATOGRAPHY MASS-SPECTROMETRIC STUDIES OF CANINE URINARY METABOLISM
    MATSUMOTO, M
    ZHANG, CH
    KOSUGI, C
    MATSUMOTO, I
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1995, 57 (02): : 205 - 211
  • [4] GAS-CHROMATOGRAPHY WITH SURFACE-IONIZATION DETECTION IN FORENSIC ANALYSIS
    HATTORI, H
    YAMADA, T
    SUZUKI, O
    JOURNAL OF CHROMATOGRAPHY A, 1994, 674 (1-2) : 15 - 23
  • [5] SOME APPLICATIONS OF THE SURFACE-IONIZATION DETECTOR IN GAS-CHROMATOGRAPHY
    FUJII, T
    JIMBA, H
    OGURA, M
    ARIMOTO, H
    OZAKI, K
    ANALYST, 1988, 113 (05) : 789 - 792
  • [6] ACTION OF DISCRIMINATION EFFECTS IN A SOURCE WITH SURFACE-IONIZATION ON THE ERROR OF MASS-SPECTROMETRIC ANALYSIS
    CHILIPENKO, LL
    MATSAEV, VT
    MIROSHNICHENKO, IV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1991, 46 (03): : 354 - 359
  • [7] DETERMINATION OF ETHYL CARBAMATE IN DISTILLED ALCOHOLIC BEVERAGES BY GAS-CHROMATOGRAPHY WITH FLAME IONIZATION OR MASS-SPECTROMETRIC DETECTION
    PIERCE, WM
    CLARK, AO
    HURST, HE
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1988, 71 (04): : 781 - 784
  • [8] DETERMINATION OF ETHYLENETHIOUREA IN WATER SAMPLES BY GAS-CHROMATOGRAPHY WITH ALKALI FLAME IONIZATION DETECTION AND MASS-SPECTROMETRIC CONFIRMATION
    VANDERPOLL, JM
    VERSLUISDEHAAN, GG
    DEWILDE, O
    JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2): : 163 - 168
  • [9] DETERMINATION OF TRACE LEVELS OF TRIMETHYLAMINE IN AIR BY GAS-CHROMATOGRAPHY SURFACE-IONIZATION ORGANIC MASS-SPECTROMETRY
    FUJII, T
    KITAI, T
    ANALYTICAL CHEMISTRY, 1987, 59 (02) : 379 - 382
  • [10] GAS-CHROMATOGRAPHY - MASS-SPECTROMETRIC CONFIRMATION OF ANABOLIC COMPOUNDS IN INJECTION SITES
    BATJOENS, P
    DEBRABANDER, HF
    SMETS, F
    POTTIE, G
    ANALYST, 1994, 119 (12) : 2607 - 2610