PUTATIVE EARLY RISK FACTORS AT BONE-IMPLANT INTERFACE IN IMMEDIATE LOADING

被引:0
|
作者
Iliescu, Alexandru-Andrei [1 ]
Iliescu, Radita [1 ]
Rusu, Darian [2 ]
Didilescu, Andreea Cristiana [1 ]
Tanase, Gabriela [1 ]
Iliescu, Andrei [1 ]
机构
[1] UMF Carol Davila Bucuresti, Bucharest, Romania
[2] UMF Victor Babes Timisoara, Timisoara, Romania
来源
关键词
osseointegration; implant surface topography; titanium wear; immediate loading;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
during osseointegration a dental implant early develops special spatial and molecular relationships wit surrounding tissues. The surface roughness and microtopography are closely related to a long-term clinical success. A better understanding of various but relevant molecules, and even of genes, that encodes biological factors involved in tissue healing should be considered useful in particular cases. Biocompatibility of implant is not yet considered as a solved problem, at infrastructural and molecular level, at least on long-term. Various biological factors, already in use, such as platelet-rich plasma, and growth factors, should be under control in order to follow a more efficient pathway towards a reliable osseointegration. A paramount attention has to be done, on long-term, to the functional modulation of bone tissue-dental implant, especially in immediate occlusal loading of dental implants.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 50 条
  • [21] BIOMECHANICAL STRESS ANALYSIS OF BONE-IMPLANT INTERFACE
    Fanali, S.
    Tramonte, S. U.
    Brunelli, G.
    Carinci, F.
    EUROPEAN JOURNAL OF INFLAMMATION, 2011, 9 (02) : 25 - 31
  • [22] Gene expression of four adhesive proteins in the early healing of bone defect and bone-implant interface
    Zhang, Ting
    Xia, Haibin
    Wang, Yining
    Peng, Cong
    Li, Yuhong
    Pan, Xinhua
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1686 - +
  • [23] Study with speckle interferometry of bone-implant interface conditions
    Simoes, J
    Monteiro, J
    Vaz, M
    Taylor, M
    Blatcher, S
    EXPERIMENTAL MECHANICS, VOLS 1 AND 2: ADVANCES IN DESIGN, TESTING AND ANALYSIS, 1998, : 851 - 855
  • [24] ELECTRON-MICROSCOPIC STUDY OF THE BONE-IMPLANT INTERFACE
    ROLAND, K
    DUFIEF, MP
    SHERIDAN, R
    HEUSON, JA
    MICRON AND MICROSCOPICA ACTA, 1987, 18 (03): : 209 - 209
  • [25] HISTOLOGY AT THE BONE-IMPLANT INTERFACE IN CEMENTED AND NONCEMENTED ENDOPROSTHESES
    HERREN, T
    REMAGEN, W
    SCHENK, R
    ORTHOPADE, 1987, 16 (03): : 239 - 251
  • [27] Immediate implants into periodontally infected sites in dogs. A histomorphometric study of bone-implant interface.
    Marcaccini, AM
    Novaes, AB
    Souza, SLS
    Taba, M
    Grisi, FFM
    Almeida, ALG
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 289 - 289
  • [28] Titania nanotubes for orchestrating osteogenesis at the bone-implant interface
    Gulati, Karan
    Maher, Shaheer
    Findlay, David M.
    Losic, Dusan
    NANOMEDICINE, 2016, 11 (14) : 1847 - 1864
  • [29] Ultrasonic Interferometric Procedure for Quantifying the Bone-Implant Interface
    Luetzelberger, Jan
    Arneth, Philipp
    Franck, Alexander
    Drese, Klaus Stefan
    SENSORS, 2023, 23 (13)
  • [30] Optimization of stress distribution of bone-implant interface (BII)
    Zhang, Chunyu
    Zeng, Chunyu
    Wang, Zhefu
    Zeng, Ting
    Wang, Yuehong
    BIOMATERIALS ADVANCES, 2023, 147