THE ROLE OF DUPLEX SCANNING VERSUS ANGIOGRAPHY IN PREDICTING OUTCOME AFTER BALLOON ANGIOPLASTY IN THE FEMOROPOPLITEAL ARTERY

被引:57
|
作者
MEWISSEN, MW [1 ]
KINNEY, EV [1 ]
BANDYK, DF [1 ]
REIFSNYDER, T [1 ]
SEABROOK, GR [1 ]
LIPCHIK, EO [1 ]
TOWNE, JB [1 ]
机构
[1] MED COLL WISCONSIN,DEPT VASC SURG,MILWAUKEE,WI 53226
关键词
D O I
10.1016/0741-5214(92)90721-J
中图分类号
R61 [外科手术学];
学科分类号
摘要
Duplex-derived velocity measurements were used to assess the hemodynamics of 64 femoropopliteal arterial sites in 59 patients after angiographically successful percutaneous transluminal balloon angioplasty. With use of angiography as the gold standard, percutaneous transluminal balloon angioplasty was judged to be successful if (1) evidence existed of a "split" caused by intimal dissection and splitting of atherosclerotic plaque; and (2) no significant diameter-reducing residual stenosis was observed at the percutaneous transluminal balloon angioplasty site. At 1 month, 55 limbs (86%) were hemodynamically and clinically improved by SVS/ISCVS clinical criteria for chronic limb ischemia. Of the 55 percutaneous transluminal balloon angioplasty sites, duplex scanning had identified 40 (63%) sites with a < 50% diameter-reducing stenosis and 15 (27%) sites with a > 50% diameter-reducing stenosis within a week after percutaneous transluminal balloon angioplasty. Independent review of the 55 angiograms taken after percutaneous transluminal balloon angioplasty identified 39 sites (71%) with a split and 16 sites (29%) without. By life-table analysis, a > 50% diameter-reducing stenosis predicted a worse clinical outcome (15% at 1 year) compared with the presence of a <50% diameter-reducing stenosis (84% at 1 year) (p < 0.001; log rank test). The presence or absence of an angiographic split was not a predictive factor of percutaneous transluminal balloon angioplasty outcome (split, 61% at 1 year; no split, 62% at 1 year) (p = 0.832; log rank test). The detection of a functional residual stenosis by duplex scanning did not correlate with angiographic appearance, but was predictive of clinical failure. Normalization of flow hemodynamics in the treated arterial segment was associated with percutaneous transluminal balloon angioplasty durability.
引用
收藏
页码:860 / 866
页数:7
相关论文
共 50 条
  • [31] Drug-coated balloon angioplasty after directional atherectomy improves outcome in restenotic femoropopliteal arteries
    Sixt, Sebastian
    Cancino, Oscar Gerardo Carpio
    Treszl, Andras
    Beschorner, Ulrich
    Macharzina, Roland
    Rastan, Aljoscha
    Krankenberg, Hans
    Neumann, Franz-Josef
    Zeller, Thomas
    JOURNAL OF VASCULAR SURGERY, 2013, 58 (03) : 682 - 686
  • [32] Predictive Factors of Femoropopliteal Patency after Suboptimal Duplex-Guided Balloon Angioplasty and Stenting: Is Recoil a Bad Sign?
    Ascher, Enrico
    Hingorani, Anil P.
    Marks, Natalie
    Puggioni, Alessandra
    Shiferson, Alexander
    Tran, Victor
    Jacob, Theresa
    VASCULAR, 2008, 16 (05) : 263 - 268
  • [33] Drug-eluting balloon angioplasty versus uncoated balloon angioplasty for the treatment of in-stent restenosis of the femoropopliteal arteries
    Kayssi, Ahmed
    Al-Jundi, Wissam
    Papia, Giuseppe
    Kucey, Daryl S.
    Forbes, Thomas
    Rajan, Dheeraj K.
    Neville, Richard
    Dueck, Andrew D.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (01):
  • [34] Re: "Cutting Balloon Versus Conventional Balloon Angioplasty in Short Femoropopliteal Arterial Stenoses" Reply
    Cotroneo, Antonio R.
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) : 629 - 630
  • [35] Safety of Paclitaxel-Coated Balloon Angioplasty for Femoropopliteal Peripheral Artery Disease
    Ouriel, Kenneth
    Adelman, Mark A.
    Rosenfield, Kenneth
    Scheinert, Dierk
    Brodmann, Marianne
    Pena, Constantino
    Geraghty, Patrick
    Lee, Arthur
    White, Roseann
    Clair, Daniel G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (24) : 2515 - 2524
  • [36] Efficacy of stent placement versus balloon angioplasty in small and short femoropopliteal lesion
    Kamioka, N.
    Soga, Y.
    EUROPEAN HEART JOURNAL, 2014, 35 : 538 - 538
  • [37] Efficacy of Stent Placement Versus Balloon Angioplasty in Small Vessel of Femoropopliteal Disease
    Kamioka, Norihiko
    Soga, Yoshimitsu
    Aihara, Hideaki
    Tomoi, Yusuke
    Kobayashi, Yohei
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (05) : 67S - 67S
  • [38] Lysis/balloon angioplasty versus thrombectomy/open patch angioplasty of failed femoropopliteal polytetrafluoroethylene bypass grafts
    AbuRahma, AF
    Hopkins, ES
    Wulu, JT
    Cook, CC
    JOURNAL OF VASCULAR SURGERY, 2002, 35 (02) : 307 - 315
  • [39] Cost-effectiveness of identifying aortoiliac and femoropopliteal arterial disease with angiography or duplex scanning
    Coffi, S. B.
    Ubbink, D. Th.
    Dijkgraaf, M. G. W.
    Reekers, J. A.
    Legemate, D. A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (01) : 142 - 148
  • [40] THE ROLE OF DUPLEX SCANNING IN THE SELECTION OF PATIENTS FOR TRANSLUMINAL ANGIOPLASTY
    EDWARDS, JM
    COLDWELL, DM
    GOLDMAN, ML
    STRANDNESS, DE
    JOURNAL OF VASCULAR SURGERY, 1991, 13 (01) : 69 - 74