LABORATORY AND CLINICAL-EVALUATION OF WHITE BLOOD-CELL DIFFERENTIAL COUNTS - COMPARISON OF THE COULTER VCS, TECHNICON H-1, AND 800-CELL MANUAL METHOD

被引:44
|
作者
SWAIM, WR
机构
[1] UNIV MINNESOTA,SCH MED,DEPT LAB MED & PATHOL,MINNEAPOLIS,MN 55455
[2] UNIV MINNESOTA,SCH MED,DEPT MED,MINNEAPOLIS,MN 55455
关键词
COULTER VCS; TECHNICON H-1; DIFFERENTIAL LEUKOCYTE COUNT; DEMING REGRESSION;
D O I
10.1093/ajcp/95.3.381
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Eight hundred-cell manual white blood cell differential count evaluations of Coulter VCSTM and Technicon H-1TM included estimates of accuracy, imprecision, random and systematic errors, clinical relevance, and detection of immature neutrophils. Accuracy was acceptable, except for H-1 testing of monocytes. Instrument imprecision was similar, except for tighter monocyte values as measured by the VCS. Deming regression determined random errors were greater for H-1 monocytes and proportional errors were similar. Constant errors for the VCS were less than the H-1 for neutrophils and monocytes and greater than the H-1 for eosinophils and lymphocytes. H-1 morphologic false-negative rates were twice those for VCS. True-positive and false-negative rates in cases with immature neutrophils were 70.6% and 20.3% for the VCS and 35% and 55.9% for the H-1. The reference false-positive rate was 4.4%. Clinically appropriate VCS flags were generated in distributionally abnormal cases. Predictive values were higher for the VCS.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 34 条
  • [1] A COMPARISON OF THE DIFFERENTIAL WHITE BLOOD-CELL COUNT USING THE TECHNICON-H1, THE TECHNICON-H6000 AND THE COULTER-VCS
    STOLSNES, B
    SKARE, EV
    TAVERNER, P
    OMMUNDSEN, T
    AGA, IB
    SANDBERG, S
    EUROPEAN JOURNAL OF HAEMATOLOGY, 1990, 45 : 37 - 39
  • [2] COMPARISON OF AUTOMATED DIFFERENTIAL BLOOD-CELL COUNTING WITH THE TECHNICON-H1 AND THE COULTER-VCS
    KATZ, N
    MARTI, B
    LENZ, T
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1988, 26 (11): : 753 - 753
  • [3] AUTOMATED DIFFERENTIAL LEUKOCYTE COUNTS IN NEWBORN-INFANTS - COMPARISON OF COULTER-VCS AND TECHNICON-H1 WITH MANUAL COUNTS
    JOHANNESSEN, B
    OMMUNDSEN, T
    MINDE, TE
    HANEBERG, B
    SANDBERG, S
    EUROPEAN JOURNAL OF HAEMATOLOGY, 1990, 45 : 41 - 44
  • [4] A COMPARISON OF DIFFERENTIAL WHITE BLOOD-CELL COUNTS USING MANUAL TECHNIQUE AND THE COULTER S-PLUS-IV
    GREENDYKE, RM
    KANTER, DR
    DEBOOVER, L
    SAVAGE, L
    VANGELDER, S
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1985, 84 (03) : 348 - 350
  • [5] LABORATORY EVALUATION OF DIFFERENTIAL WHITE BLOOD-CELL COUNT INFORMATION FROM THE COULTER S-PLUS IV AND TECHNICON H-1 IN PATIENT POPULATIONS REQUIRING RAPID TURNAROUND TIME
    NELSON, L
    CHARACHE, S
    WINGFIELD, S
    KEYSER, E
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (05) : 563 - 569
  • [6] A COMPARISON OF DIFFERENTIAL WHITE CELL COUNTING ON THE COULTER VCS AND THE TECHNICON-H1 USING SIMPLE AND MULTIPLE-REGRESSION ANALYSIS
    DRAYSON, RA
    HAMILTON, MSH
    ENGLAND, JM
    CLINICAL AND LABORATORY HAEMATOLOGY, 1992, 14 (04): : 293 - 305
  • [7] ANALYTICAL ERRORS OF MANUAL AND AUTOMATED WHITE BLOOD-CELL DIFFERENTIAL COUNTS
    DREWINKO, B
    BOLLINGER, PB
    BRAILAS, CD
    DANIELS, P
    JOHNSTON, D
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 87 (03) : 418 - 418
  • [8] LEUKEMIC BLASTS DETECTED BY THE TECHNICON H-1 BLOOD-CELL COUNTER
    KAWARABAYASHI, K
    TSUDA, I
    TATSUMI, N
    OKUDA, K
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (05) : 624 - 627
  • [9] AUTOMATION OF BLOOD-CELL COUNTS AND DIFFERENTIAL WHITE CELL COUNTS EVALUATION OF 5 SYSTEMS
    LEGLISE, MC
    COLIN, F
    BLOUCH, MT
    LEROUX, AM
    ANNALES DE BIOLOGIE CLINIQUE, 1982, 40 (04) : 491 - 491
  • [10] A COMPARISON OF THE COULTER STKS, COULTER S+IV, AND MANUAL ANALYSIS OF WHITE BLOOD-CELL DIFFERENTIAL COUNTS IN A HUMAN IMMUNODEFICIENCY VIRUS-INFECTED POPULATION
    COHEN, AJ
    PEERSCHKE, EIB
    STEIGBIGEL, RT
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (06) : 611 - 617