EVIDENCE OF RISE IN BLOOD-PRESSURE DUE TO INFLATING THE CUFF - EFFECTS ON SELF-RECORDED BLOOD-PRESSURE

被引:0
|
作者
ECKERT, S [1 ]
GLEICHMANN, S [1 ]
OHLMEIER, H [1 ]
SCHMIDT, HK [1 ]
GLEICHMANN, U [1 ]
机构
[1] RUHR UNIV BOCHUM KLIN,HERZ & DIABET ZENTRUM,KARDIOL KLIN,BAD OEYNHAUSEN,GERMANY
关键词
RISE IN BLOOD PRESSURE; MUSCLE ACTIVITY; SELF INFLATE A CUFF;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
We studied in 50 men (each group 10 nontreated and treated normotensives and hypertensives and heart transplants) the influence on blood pressure of the muscle activity needed to self inflate a cuff. A significant rise in blood pressure was found in all 5 groups: for systolic values 18 to 25 mmHg, for diastolic values 13 to 16 mmHg. The duration of the transient rise in blood pressure was 13 to 15 seconds. Self-recorded systolic blood pressure may be measured as too high when patients inflate their cuff at too low pressure and/or deflate it too fast, an automatic device with a pump could be used to eliminate the effects of manuel cuff inflation.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 50 条
  • [1] EFFECTS OF CUFF INFLATION ON SELF-RECORDED BLOOD-PRESSURE
    VEERMAN, DP
    VANMONTFRANS, GA
    WIELING, W
    [J]. LANCET, 1990, 335 (8687): : 451 - 453
  • [2] INFLATING ONES OWN CUFF DOES NOT INCREASE SELF-RECORDED BLOOD-PRESSURE
    VEERMAN, DP
    VANMONTFRANS, GA
    KAREMAKER, JM
    WIELING, W
    [J]. JOURNAL OF HYPERTENSION, 1988, 6 : S77 - S78
  • [3] HOME MEASUREMENT WITH CONFIDENCE - DISTRIBUTION OF SELF-RECORDED BLOOD-PRESSURE IN SUBJECTS WITH LOW BLOOD-PRESSURE
    KUYCK, WGE
    MONTFRANS, GAV
    [J]. JOURNAL OF HYPERTENSION, 1989, 7 : S378 - S378
  • [4] AN EVALUATION OF SELF-RECORDED BLOOD-PRESSURE DURING DRUG TRIALS
    GOULD, BA
    HORNUNG, RS
    KIESO, H
    CASHMAN, PMM
    RAFTERY, EB
    [J]. HYPERTENSION, 1986, 8 (04) : 267 - 271
  • [5] CROSSOVER DESIGN TO TEST ANTIHYPERTENSIVE DRUGS WITH SELF-RECORDED BLOOD-PRESSURE
    MENARD, J
    SERRURIER, D
    BAUTIER, P
    PLOUIN, PF
    CORVOL, P
    [J]. HYPERTENSION, 1988, 11 (02) : 153 - 159
  • [6] LENGTH OF BLOOD-PRESSURE CUFF
    BAILIE, MD
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 1976, 114 (06) : 496 - 496
  • [7] BLOOD-PRESSURE CUFF CONFUSION
    LOGGIE, J
    [J]. PEDIATRICS, 1988, 81 (02) : 328 - 329
  • [8] BLOOD-PRESSURE CUFF SIZE
    HERNDON, RF
    [J]. LANCET, 1982, 2 (8298): : 610 - 610
  • [9] BLOOD-PRESSURE CUFF CONTROVERSY
    COHEN, ML
    ALEXANDER, H
    STEINFELD, L
    [J]. PEDIATRICS, 1978, 61 (01) : 161 - 161
  • [10] CUFF SIZE AND BLOOD-PRESSURE
    GOLLIN, S
    [J]. LANCET, 1990, 336 (8719): : 887 - 887