Although the medial phalanx has been recommended as the preferred site for recording skin conductance activity, a review of articles published in Psychophysiology indicates that a large minority (34%) of studies employ the distal phalanx. Informal observations also suggest that the distal site may be more reactive than the medial site. This study formally tests this observation by recording skin conductance from both medial and distal phalanges. Twenty-four right-handed subjects (12 male, 12 female) were exposed to a series of 10 orienting and defensive stimuli. Electrodes were placed on the fore and middle fingers of each hand, with distal sites used on one hand and medial sites on the other for each subject. Skin conductance amplitudes were 3.5 times larger at distal than medial sites (p < .002), while skin conductance levels were 2.08 times larger at distal sites (p < .0005). A significant Site X Stimulus interaction (p < .025) indicated that the distal site was more sensitive to habituation over trials and to increases in skin conductance amplitudes with increasing stimulus intensity than the medial site. On the basis of these findings it is recommended that distal sites be used in preference to medial sites in the recording of skin conductance activity.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 50 条
  • [21] Instantaneous measurement of electrical parameters in a palm during electrodermal activity
    Yamamoto, Y
    Isshiki, H
    Nakamura, T
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (02) : 483 - 487
  • [22] Toward Mental Effort Measurement Using Electrodermal Activity Features
    Romine, William
    Schroeder, Noah
    Banerjee, Tanvi
    Graft, Josephine
    SENSORS, 2022, 22 (19)
  • [23] Electrodermal Activity Monitoring With Flexible Dry Electrodes and AC Measurement
    Shishavan, Hossein Hamidi
    Severgnini, Frederico Marcolino Quintao
    Singh, Parveen
    Schmalenberg, Paul
    Dede, Ercan M.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [24] A COMPARISON OF TWO MEASUREMENT TECHNOLOGIES TO COLLECT ELECTRODERMAL ACTIVITY IN INFANTS
    DiCorcia, Jennifer A.
    Goodwin, Matthew S.
    Hedman, Elliott B.
    Snidman, Nancy
    PSYCHOPHYSIOLOGY, 2012, 49 : S107 - S107
  • [25] Measurement, time-stamping and analysis of electrodermal activity in fMRI
    Smyser, C
    Grabowski, T
    Rainville, P
    Bechara, A
    Razavi, M
    Mehta, S
    Eaton, B
    Bolinger, L
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 470 - 475
  • [26] Electrodermal activity
    Lagopoulos, Jim
    ACTA NEUROPSYCHIATRICA, 2007, 19 (05) : 316 - 317
  • [27] Effect of facial familiarity and task requirement on electrodermal activity
    Shearer, D
    Mikulka, P
    AMERICAN JOURNAL OF PSYCHOLOGY, 1996, 109 (01): : 131 - 137
  • [28] Design evaluation by combination of repeated evaluation technique and measurement of electrodermal activity
    Carbon, Claus-Christian
    Michael, Lars
    Leder, Helmut
    RESEARCH IN ENGINEERING DESIGN, 2008, 19 (2-3) : 143 - 149
  • [30] Design evaluation by combination of repeated evaluation technique and measurement of electrodermal activity
    Claus-Christian Carbon
    Lars Michael
    Helmut Leder
    Research in Engineering Design, 2008, 19 : 143 - 149