HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF IMIDAZOLIUM AND PYRIDINIUM OXIMES IN PLASMA AND URINE

被引:4
|
作者
SHIH, ML
SMITH, JR
SALEM, GW
机构
[1] U.S. Army Medical Research Institute of Chemical Defense, Aberdeen Proving Ground
来源
关键词
D O I
10.1016/S0378-4347(00)82120-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Imidazolium oximes are useful in the treatment of organophosphorus agent poisoning. However, the extant methods for analyzing oximes in plasma and urine samples are not adequate. A unique high-performance liquid chromatographic assay method was developed for quantitating either imidazolium or pyridinium oximes. Plasma or urine samples can be injected directly onto the column after a centrifugation filtration step. This method demonstrates a different approach in the method development for quaternary ammonium compounds using non-end-capped reversed-phase columns and a mobile phase containing competing cations. In addition, a preliminary pharmacokinetic study of the imidazolium oxime in rabbits was carried out using this method. © 1990.