DEVELOPMENT AND VALIDATION OF A COMPETITIVE ENZYME-IMMUNOASSAY FOR CHUM SALMON PROLACTIN - A COMPARISON TO RADIOIMMUNOASSAY

被引:4
|
作者
TAKAHASHI, A
YASUDA, A
KAWAUCHI, H
HIRANO, T
机构
[1] KITASATO UNIV,SCH FISHERIES SCI,MOLEC ENDOCRINOL LAB,SANRIKU,IWATE 02201,JAPAN
[2] UNIV TOKYO,OCEAN RES INST,TOKYO 164,JAPAN
关键词
D O I
10.1016/0016-6480(90)90186-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An enzyme immunoassay (EIA), based on a competitive assay system, for the measurement of prolactin (PRL) in the pituitary of salmonid fishes and of hormone released in medium from incubated pituitary was developed using a rabbit antiserum to chum salmon PRL (PRL, a combination of PRL I and PRL II). Chum salmon PRL was coupled to horseradish peroxidase (HRP). The incubation procedure for the antigen-antibody reaction was analogous to that in the radioimmunoassay (RIA) for PRL. The antibody-bound HRP-PRL was separated by a double antibody method. The enzyme activity in the precipitate was followed by a colorimetric method, in which 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) and o-phenylenediamine were used as substrates. PRL, PRL I, and PRL II showed exactly the same competitive curves in the EIA system. PRL (127-158) showed the highest cross-reactivity among the fragments of PRL examined. Low cross-reactivity was seen with other hormones isolated from chum salmon pituitary. The displacement curves for pituitary extracts from several salmonids, including chum salmon, coho salmon, and rainbow trout, were parallel to that of the PRL standard, whereas those from the carp and tilapia showed negligible cross-reactivity. A parallel displacement curve to the PRL standard was also seen with incubation medium of the pars distalis of the chum salmon pituitary. Plasma from chum salmon, coho salmon, and rainbow trout gave nonspecific HRP activity in the EIA. The values of PRL-EIA were significantly correlated (y = 0.99x + 1.06, r = 0.942, P < 0.05, n = 24) with those obtained in PRL-RIA. The ED50 of PRL-EIA was 11.5 ± 0.86 ng (n = 10). The interassay coefficient was 23.7% at ED50 (n = 10). Intraassay coefficients of variation were 12.8% at 5 ng and 10.6% at 20 ng (n = 10). © 1990.
引用
下载
收藏
页码:372 / 380
页数:9
相关论文
共 50 条
  • [41] COMPETITIVE ENZYME-IMMUNOASSAY FOR HUMAN-PLASMA FIBRONECTIN
    VUENTO, M
    SALONEN, E
    PASANEN, M
    STENMAN, UH
    JOURNAL OF IMMUNOLOGICAL METHODS, 1981, 40 (01) : 101 - 108
  • [42] TECHNICON PROLACTIN - A FULLY AUTOMATED ENZYME-IMMUNOASSAY FOR THE DETERMINATION OF PROLACTIN IN HUMAN SERUM
    DELLAPUCA, R
    WEITZ, S
    DANISCH, R
    HIXSON, C
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1100 - 1100
  • [43] DETERMINATION OF TOTAL THYROXINE WITH HOMOGENEOUS ENZYME-IMMUNOASSAY - COMPARISON OF MANUAL AND AUTOMATED ENZYME-IMMUNOLOGICAL DETERMINATION WITH RADIOIMMUNOASSAY
    VOGT, W
    TAUSCH, A
    EBENROTH, S
    DURMEYER, E
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1978, 290 (02): : 97 - 98
  • [44] A COMPARISON OF RADIOIMMUNOASSAY VS ENZYME-IMMUNOASSAY MEASUREMENT OF FERRITIN CONCENTRATION IN PRE AND POST MENOPAUSAL FEMALES
    BRADLEY, CA
    CREAN, DM
    POSEY, YF
    PARL, FF
    CLINICAL CHEMISTRY, 1987, 33 (06) : 1032 - 1032
  • [45] CARCINOEMBRYONIC ANTIGEN - COMPARISON OF RADIOIMMUNOASSAY AND ENZYME-IMMUNOASSAY IN POSTOPERATIVE SURVEILLANCE OF PATIENTS WITH CARCINOMA OF THE COLON OR RECTUM
    WINTZER, G
    CORMAN, G
    UHLENBRUCK, G
    LEBER MAGEN DARM, 1979, 9 (06) : 307 - 309
  • [46] DEVELOPMENT OF AN ENZYME-IMMUNOASSAY FOR CRYPTOCOCCAL ANTIBODY
    SCOTT, EN
    FELTON, FG
    MUCHMORE, HG
    MYCOPATHOLOGIA, 1980, 70 (01) : 55 - 59
  • [47] MEASUREMENT OF CA-125 BY AN AUTOMATED MICROPARTICLE ENZYME-IMMUNOASSAY - COMPARISON WITH A MANUAL ENZYME-IMMUNOASSAY
    MOGENSEN, O
    MOGENSEN, B
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1992, 52 (06): : 507 - 512
  • [48] PREDICTIVE VALUE OF ANTINATIVE DNA FOR SYSTEMIC LUPUS-ERYTHEMATOSUS - COMPARISON OF RADIOIMMUNOASSAY AND ENZYME-IMMUNOASSAY
    CLOUGH, JD
    CHANG, RK
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1989, 3 (05) : 273 - 276
  • [49] DEVELOPMENT AND APPLICATION OF AN ENZYME-IMMUNOASSAY FOR TENASCIN
    WASHIZU, K
    KIMURA, S
    HIRAIWA, H
    MATSUNAGA, K
    KUWABARA, M
    ARIYOSHI, Y
    KATO, K
    TAKEUCHI, K
    CLINICA CHIMICA ACTA, 1993, 219 (1-2) : 15 - 22
  • [50] DEVELOPMENT OF AN ENZYME-IMMUNOASSAY FOR METOLACHLOR IN WATER
    BRADY, JF
    CHEUNG, MW
    TURNER, J
    SKINNER, DH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 84 - AGRO