CARBON-PASTE ELECTRODES WITH INCORPORATED LACTATE OXIDASE AND MEDIATORS

被引:55
|
作者
KULYS, J [1 ]
SCHUHMANN, W [1 ]
SCHMIDT, HL [1 ]
机构
[1] INST BIOCHEM, VILNIUS 2600, USSR
关键词
L-LACTATE; GRAPHITE; CARBON PASTE; L-LACTATE OXIDASE; FERROCENE; 1,1'-DIMETHYLFERROCENE; N; N-DIMETHYLAMINOMETHYLFERROCENE; MELDOLA BLUE;
D O I
10.1080/00032719208020055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric bioelectrodes based on carbon paste modified with L-lactate oxidase and mediators are described which are sensitive to L-lactate. Several ferrocenes and phenoxazine derivatives as mediators are evaluated, with Meldola blue exhibiting the best results. With ferrocene derivatives the bioelectrodes were operated at potential of 0.2-0.4 V (vs SCE). The apparent Michaelis constants for the calibration curves of the bioelectrodes are different depending on the chosen mediator and varied in the range from 0.9 to 3.6 mM L-lactate. The pH optimum in the case of the 1,1'-dimethylferrocene bioelectrode was 9.3 and the limiting sensitivity was determined to be 31-mu-A/mM cm-2. Covered by a Nafion membrane, the electrode sensitivity was in the range of 3.2-4.4-mu-A/mM cm-2 at pH 7.0 and the calibration range was linear up to 2-2.5 mM L-lactate. The bioelectrode based on Meldola blue mediated electron transfer at potentials between 0.05-0.25 V. The K(m)(app) was 17.0 and 18.2 mM at 0.1 and 0.05 V, respectively. The pH optimum of the bioelectrodes was 7.9 and limiting sensitivity - 164-mu-A/mM cm-2. At normal physiological level of ascorbic acid (50-mu-M) in blood the response of the Meldola blue based sensors was 5.3 % at 0.1 V, whereas that of the 1,1'-dimethylferrocene bioelectrode was 83 % at 0.25 V in comparison to the response observed with physiological levels of L-lactate (2 mM).
引用
收藏
页码:1011 / 1024
页数:14
相关论文
共 50 条
  • [21] The manufacture of continuous smelting electrodes from carbon-paste briquettes
    Fitt, AD
    Howell, PD
    JOURNAL OF ENGINEERING MATHEMATICS, 1998, 33 (04) : 353 - 376
  • [22] Preconcentration and Voltammetric Determination of Nitro Compounds on Carbon-Paste Electrodes
    S. V. Sapel'nikova
    N. V. Kuz'mina
    V. N. Maistrenko
    F. Kh. Kudasheva
    Journal of Analytical Chemistry, 2002, 57 : 443 - 447
  • [23] Preconcentration and voltammetric determination of nitro compounds on carbon-paste electrodes
    Sapel'nikova, SV
    Kuz'mina, NV
    Maistrenko, VN
    Kudasheva, FK
    JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (05) : 443 - 447
  • [24] CARBON-PASTE ELECTRODES WITH ELECTROLYTIC BINDER - INFLUENCE OF THE PREPARATION METHOD
    RAMIREZ, MT
    PALOMAR, ME
    GONZALEZ, I
    ROJASHERNANDEZ, A
    ELECTROANALYSIS, 1995, 7 (02) : 184 - 188
  • [25] VOLTAMMETRIC CHARACTERIZATION OF ACTIVATED CARBONS IN MODIFIED CARBON-PASTE ELECTRODES
    KAPLAN, JD
    MARSH, JH
    ORCHARD, SW
    ELECTROANALYSIS, 1993, 5 (5-6) : 509 - 516
  • [26] The Manufacture of Continuous Smelting Electrodes from Carbon-Paste Briquettes
    A.D. Fitt
    P.D. Howell
    Journal of Engineering Mathematics, 1998, 33 : 353 - 376
  • [27] HUMIC ACIDS INTERACTIONS WITH METAL-SALTS INCORPORATED INTO THE CARBON-PASTE ELECTRODE
    KULA, P
    NAVRATILOVA, Z
    ELECTROANALYSIS, 1994, 6 (11-12) : 1009 - 1013
  • [28] DETERMINATION OF IRON(II) WITH CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODES
    GAO, ZQ
    LI, PB
    ZHAO, ZF
    TALANTA, 1991, 38 (10) : 1177 - 1184
  • [29] THE USE OF CARBON-PASTE ELECTRODES WITH NONCONDUCTING BINDER FOR THE STUDY OF MINERALS - CHALCOPYRITE
    LAZARO, I
    MARTINEZMEDINA, N
    RODRIGUEZ, I
    ARCE, E
    GONZALEZ, I
    HYDROMETALLURGY, 1995, 38 (03) : 277 - 287
  • [30] Use of carbon-paste electrodes modified with macrocyclic compounds in voltammetric analysis
    Shajdarova, L.G.
    Ulakhovich, N.A.
    Al'-Gakhri, M.A.
    Budnikov, G.K.
    Glebov, A.N.
    Zhurnal Analiticheskoi Khimii, 50 (07): : 755 - 760