CARBON-PASTE ELECTRODES WITH INCORPORATED LACTATE OXIDASE AND MEDIATORS

被引:55
|
作者
KULYS, J [1 ]
SCHUHMANN, W [1 ]
SCHMIDT, HL [1 ]
机构
[1] INST BIOCHEM, VILNIUS 2600, USSR
关键词
L-LACTATE; GRAPHITE; CARBON PASTE; L-LACTATE OXIDASE; FERROCENE; 1,1'-DIMETHYLFERROCENE; N; N-DIMETHYLAMINOMETHYLFERROCENE; MELDOLA BLUE;
D O I
10.1080/00032719208020055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric bioelectrodes based on carbon paste modified with L-lactate oxidase and mediators are described which are sensitive to L-lactate. Several ferrocenes and phenoxazine derivatives as mediators are evaluated, with Meldola blue exhibiting the best results. With ferrocene derivatives the bioelectrodes were operated at potential of 0.2-0.4 V (vs SCE). The apparent Michaelis constants for the calibration curves of the bioelectrodes are different depending on the chosen mediator and varied in the range from 0.9 to 3.6 mM L-lactate. The pH optimum in the case of the 1,1'-dimethylferrocene bioelectrode was 9.3 and the limiting sensitivity was determined to be 31-mu-A/mM cm-2. Covered by a Nafion membrane, the electrode sensitivity was in the range of 3.2-4.4-mu-A/mM cm-2 at pH 7.0 and the calibration range was linear up to 2-2.5 mM L-lactate. The bioelectrode based on Meldola blue mediated electron transfer at potentials between 0.05-0.25 V. The K(m)(app) was 17.0 and 18.2 mM at 0.1 and 0.05 V, respectively. The pH optimum of the bioelectrodes was 7.9 and limiting sensitivity - 164-mu-A/mM cm-2. At normal physiological level of ascorbic acid (50-mu-M) in blood the response of the Meldola blue based sensors was 5.3 % at 0.1 V, whereas that of the 1,1'-dimethylferrocene bioelectrode was 83 % at 0.25 V in comparison to the response observed with physiological levels of L-lactate (2 mM).
引用
收藏
页码:1011 / 1024
页数:14
相关论文
共 50 条
  • [1] HIGHLY SELECTIVE BIOSENSING OF LACTATE AT LACTATE OXIDASE CONTAINING RHODIUM-DISPERSED CARBON-PASTE ELECTRODES
    WANG, J
    CHEN, Q
    PEDRERO, M
    [J]. ANALYTICA CHIMICA ACTA, 1995, 304 (01) : 41 - 46
  • [2] PREPARATION AND PROPERTIES OF CARBON-PASTE ELECTRODES
    SVANCARA, I
    VYTRAS, K
    [J]. CHEMICKE LISTY, 1994, 88 (03): : 138 - 146
  • [3] APPLICATIONS OF CARBON-PASTE ELECTRODES IN ELECTROANALYSIS
    VYTRAS, K
    SVANCARA, I
    [J]. CHEMICKE LISTY, 1994, 88 (07): : 412 - 422
  • [4] ACTIVATED CARBON-PASTE ELECTRODES FOR BIOSENSORS
    MOTTA, N
    GUADALUPE, AR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (04) : 566 - 571
  • [5] CEPHALOSPORIN ANTIBIOTICS AT CARBON-PASTE AND MODIFIED CARBON-PASTE ELECTRODES IN BOTH AQUEOUS AND BIOLOGICAL MEDIA
    ELMAALI, NA
    GHANDOUR, MA
    KAUFFMANN, JM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1995, 38 (01): : 91 - 97
  • [6] CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS
    GORTON, L
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 23 - 45
  • [7] Evaluation of redox mediators for amperometric biosensors: Ru-complex modified carbon-paste/enzyme electrodes
    Ivanova, EV
    Sergeeva, VS
    Oni, J
    Kurzawa, C
    Ryabov, AD
    Schuhmann, W
    [J]. BIOELECTROCHEMISTRY, 2003, 60 (1-2) : 65 - 71
  • [8] AN ELECTROCHEMICAL STUDY OF REDUCED ILMENITE CARBON-PASTE ELECTRODES
    MARINOVICH, Y
    BAILEY, S
    AVRAAMIDES, J
    JAYASEKERA, S
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 1995, 25 (09) : 823 - 832
  • [9] Comparison of oxygren-rich and mediator-based glucose-oxidase carbon-paste electrodes
    Wang, J
    Mo, JW
    Li, SF
    Porter, J
    [J]. ANALYTICA CHIMICA ACTA, 2001, 441 (02) : 183 - 189
  • [10] VOLTAMMETRIC INVESTIGATIONS ON CARBON-PASTE ELECTRODES AS SUPPORTS FOR MERCURY FILMS
    SVANCARA, I
    PRAVDA, M
    HVIZDALOVA, M
    VYTRAS, K
    KALCHER, K
    [J]. ELECTROANALYSIS, 1994, 6 (08) : 663 - 671