Initial US evaluation of second-generation capsule colonoscopy for detecting colon polyps

被引:8
|
作者
Morgan, Douglas R. [1 ]
Malik, Pramod R. [2 ]
Romeo, David P. [3 ]
Rex, Douglas K. [4 ]
机构
[1] Vanderbilt Univ, Dept Med, Div Gastroenterol Hepatol & Nutr, Vanderbilt Inst Global Hlth, Nashville, TN 37232 USA
[2] Gastroenterol Associates Tidewater PC, Virginia Gastroenterol Inst, Suffolk, VA USA
[3] Dayton Gastroenterol Inc, Beavercreek, OH USA
[4] Indiana Univ Hosp, Dept Med, Div Gastroenterol Hepatol, 550 N Univ Blvd, Indianapolis, IN 46202 USA
来源
BMJ OPEN GASTROENTEROLOGY | 2016年 / 3卷 / 01期
关键词
D O I
10.1136/bmjgast-2016-000089
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: Capsule colonoscopy is an additional screening modality for colorectal cancer. Secondgeneration capsule colonoscopy (CC2) may have improved efficacy in the detection of colon adenomas as compared with prior devices. The purpose of this study was to evaluate the performance of CC2 in the detection of polyps in symptomatic and screening patients in the USA. Design: Prospective, multicentre study. Setting and participants: Two academic medical centres and two private practice facilities, evaluating patients with indications for colonoscopy. Methods: Patients underwent capsule colonoscopy procedure using magnesium citrate as a boost, followed by colonoscopy on the same day. The main outcome measurement was accuracy of CC2 for the detection of colorectal polyps >= 6 and >= 10 mm as compared with conventional colonoscopy. Results: 51 patients were enrolled, 50 of whom had CC2 and colonoscopy examinations and were included in the accuracy analysis. 30% and 14% of patients had polyps >= 6 and >= 10 mm, respectively. For lesions >= 10 mm identified on conventional colonoscopy, CC2 sensitivity was 100% (95% CI 56.1% to 100%) with a specificity of 93.0% (79.9% to 98.2%). For polyps >= 6 mm, the CC2 sensitivity was 93.3% (66.0% to 99.7%) and the specificity was 80.0% (62.5% to 90.9%). There was a 61% adequate cleansing rate with 64% of CC2 procedures being complete. Conclusions: In the initial US experience with CC2 there was adequate sensitivity for detecting patients with polyps >= 6 mm in size. Magnesium citrate was inadequate as a boost agent.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Evaluation of the cardiac safety of second-generation antihistamines
    Taglialatela, M
    Annunziato, L
    ALLERGY, 2000, 55 : 22 - 30
  • [42] Evaluation of a second-generation thyrotropin automated immunoassay
    BoonFalleur, L
    DeNayer, P
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1996, 34 (01): : 73 - 76
  • [43] Accuracy of First- and Second-Generation Colon Capsules in Endoscopic Detection of Colorectal Polyps: A Systematic Review and Meta-analysis
    Spada, Cristiano
    Pasha, Shabana F.
    Gross, Seth A.
    Leighton, Jonathan A.
    Schnoll-Sussman, Felice
    Correale, Loredana
    Suarez, Begona Gonzalez
    Costamagna, Guido
    Hassan, Cesare
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2016, 14 (11) : 1533 - +
  • [44] The second-generation eCLIPs Endovascular Clip System: initial experience
    Chiu, Albert H.
    De Vries, Joost
    O'Kelly, Cian J.
    Riina, Howard
    McDougall, Ian
    Tippett, Jonathan
    Wan, Martina
    Manoel, Airton Leonardo de Oliveira
    Marotta, Thomas R.
    JOURNAL OF NEUROSURGERY, 2018, 128 (02) : 482 - 489
  • [45] Analyses of second-generation 'legal highs' in the UK: Initial findings
    Brandt, Simon D.
    Sumnall, Harry R.
    Measham, Fiona
    Cole, Jon
    DRUG TESTING AND ANALYSIS, 2010, 2 (7-8) : 377 - 382
  • [46] Pillcam colon capsule endoscopy compared to colonoscopy in detection of colon polyps and cancers. interim analysis of a prospective multicentre trial
    Postgate, A. J.
    Fraser, C.
    Fitzpatrick, A.
    Munoz-Navas, M.
    Fernandez-Urien, I.
    Lapalus, M.
    Ponchon, T.
    Gay, G.
    Delvaux, M.
    Neuhaus, H.
    Philliper, M.
    Costamagna, G.
    Riccioni, M.
    Spada, C.
    Haegenmuller, F.
    Keuchel, M.
    Schoofs, N.
    Van Gossum, A.
    Deviere, J.
    GUT, 2008, 57 : A47 - A47
  • [47] Evaluation of tumor angiogenesis with a second-generation US contrast medium in a rat breast tumor model
    Ko, Eun Young
    Lee, Sang Hoon
    Kim, Hak Hee
    Kim, Sung Moon
    Shin, Myung Jin
    Kim, Namkug
    Gong, Gyungyub
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (03) : 243 - 249
  • [48] The first second-generation adenosine drug enters the US market
    Pelleg, Amir
    Belardinelli, Luiz
    PURINERGIC SIGNALLING, 2008, 4 (04) : 407 - 408
  • [49] The first second-generation adenosine drug enters the US market
    Amir Pelleg
    Luiz Belardinelli
    Purinergic Signalling, 2008, 4 : 407 - 408
  • [50] Evaluation of second-generation photoacoustic mammography in detecting the breast cancer vasculature and hypoxic status; a preliminary study
    Kawashima, Masahiro
    Yamaga, Iku
    Torii, Masae
    Tokiwa, Mariko
    Elham, Fakhrejahani
    Kataoka, Masako
    Kanao, Shotaro
    Takada, Masahiro
    Asao, Yasufumi
    Shiina, Tsuyoshi
    Toi, Masakazu
    CANCER RESEARCH, 2015, 75